NaceCare Solutions TTB1620T Manuel d'utilisation

Page 27

Advertising
background image

27

!

!

The floor-tool

Fig 35

Fig 37

Fig 38

Fig 36

To clean the floor-tool, remove securing-pin and pull-free from the holder (see Fig 35).

Rinse the floor-tool assembly with clean water and refit.

Periodically the floor-tool blades should be examined and checked for wear and damage.

The blade removal is easy. Simply start by removing the four retaining pins (Fig 36), turn the

floor-tool over and separate the blade carrier from the body (Fig 37).

Peel away the blades from their locating lugs (Fig 38) and examine or renew as required.

Replacement is a reversal of the removal process.

Floor-tool overview

1. Floor-tool main body
2. Rear blade
3. Blade carrier
4. Front blade (slotted)
5. Retaining pins x 4

1

2

3

4

5

ALWAYS ENSURE THAT THE MACHINE IS SWITCHED OFF PRIOR TO ANY

MAINTENANCE USING THE MASTER CONTROL ON/OFF KEY.

REMOVE THE KEY PRIOR TO ANY MAINTENCANCE OPERATION.

Changing the Floor Tool Blades

Advertising