Sample, 3 general information, 4 rating plate information – Napoleon Fireplaces GDI44 Manuel d'utilisation
Page 6: Gdi44

6
W415-0734 / D / 02.03.12
2.3 GENERAL
INFORMATION
61.4%
GDI44
When the appliance is installed at elevations above 4,500ft, and in the absence of specifi c recommendations
from the local authority having jurisdiction, the certifi ed high altitude input rating shall be reduced at the rate of
4% for each additional 1,000ft.
Expansion / contraction noises during heating up and cooling down cycles are normal and to be expected.
In order to achieve maximum turn down rate, the rear burner must be turned off. See Operating Instructions in
the owner's manual for more information.
This appliance is not approved for closet or recessed installations. It is approved for bathroom, bedroom and
bed-sitting room installations and is suitable for mobile homes. The natural gas model is suitable for installation
in a mobile home that is permanently positioned on its site and fuelled with natural gas.
This appliance must be recessed into a vented noncombustible wood-burning fi replace (prefabricated or
masonry) only.
GDI44
NG
LP
Altitude (FT)
0-4,500
0-4,500
Max. Input (BTU/HR)
40,000
40,000
Max. Output (BTU/HR)
27,600
27,600
Effi ciency (w/the fan on)
69%
69%
Min. Inlet Gas Supply
Pressure
4.5" Water Column
11" Water Column
Max. Inlet Gas Supply
Pressure
7" Water Column
13" Water Column
Manifold Pressure (Under
Flow Conditions)
3.5" Water Column
10" Water Column
FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS
OPERATION AND QUALITY!
2.4 RATING PLATE INFORMATION
W385-0252 / F
SERIAL NUMBER
NO. DE SERIE
GDI / CDI-44
GDI-44N / CDI-44N
MODEL
GDI-44P / CDI-44P
0 - 4500FT
ALTITUDE/ELEVATION
0 - 4500FT
40,000 BTU/h
INPUT / ALIMENTATION
40,000 BTU/h
13,000 BTU/h
REDUCED INPUT / ALIMENTATION REDUITE
10,000 BTU/h
THIS FIREPLACE USES AND REQUIRES A FAST ACTING THERMOCOUPLE. REPLACE
ONLY WITH A FAST ACTING THERMOCOUPLE SUPPLIED BY WOLF STEEL LTD.
APPROVED FOR BEDROOM, BATHROOM & BEDSITTING ROOM INSTALLATION. SUITABLE
FOR MOBILE HOME INSTALLATION IF INSTALLED IN ACCORDANCE WITH THE CURRENT
STANDARD CAN/CSA Z240MH SERIES GAS EQUIPPED MOBILE HOMES, IN CANADA OR IN
THE UNITED STATES THE MANUFACTURED HOME CONSTRUCTION AND SAFETY
STANDARD, TITLE 24 CFR, PART 3280. WHEN THIS US STANDARD IS NOT APPLICABLE
USE THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFACTURED HOME
INSTALLATIONS, SITES AND COMMUNITIES, ANSI / NFPA 501A.
HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE A COUCHER, UNE SALLE DE
BAIN ET UN STUDIO. APPROPRIE POUR INSTALLATION DANS UNE MAISON MOBILE SI
SON INSTALLATION CONFORME AUX EXIGENCES DE LA NORME CAN/CSA Z240MH
SERIE DE MAISONS MOBILES EQUIPEES AU GAZ, EN VIGUEUR AU CANADA OU AUX
ETATS-UNIS DE LA NORME DE SECURITE ET DE CONSTRUCTION DE MAISONS
MANUFACTUREES, TITRE 24 CFR, SECTION 3280. DANS LE CAS OU CETTE NORME
D'ETATS-UNIS NE PEUT ETRE APPLIQUEE, SE REFERER A LA NORME RELATIVE AU
CRITERE DE MESURES DE SECURITE CONTRE L'INCENDIE POUR LES INSTALLATIONS
DANS LES MAISONS MANUFACTURES, LES SITES ET LES COMMUNAUTES, ANSI/NFPA
501A.
MINIMUM AND MAXIMUM VERTICAL VENT LENGTHS ARE 7 FEET AND 40 FEET
RESPECTIVELY. LES LONGUEURS VERTICALES MINIMALES ET MAXIMALES SONT 7
PIEDS ET 40 PIEDS RESPECTIVEMENT.
MANIFOLD PRESSURE: 3.5 INCHES W.C. (NG) / 10 INCHES W.C.(LP)
PRESSION AU COLLECTEUR : 3.5" D'UNE COLONNE D'EAU(GN) / 10" D'UNE COLONNE
D'EAU (P)
MIN SUPPLY PRESSURE: 4.5" W.C.(NG) / 11" W.C. (LP)
PRESSION D'ALIMENTATION MIN : 4.5" D'UNE COLONNE D'EAU (GN) / 11" D'UNE
COLONNE D'EAU (P)
MAX. SUPPLY PRESSURE: 7" W.C. (NG) / 13" W.C. (LP)
PRESSION D'ALIMENTATION MAX : 7" D'UNE COLONNE D'EAU (GN) / 13" D'UNE
COLONNE D'EAU (P)
FOR USE WITH GLASS DOORS CERTIFIED WITH THIS UNIT ONLY.
UTILISER AVEC LES PORTES VITREES HOMOLOGUEES SEULEMENT AVEC CETTE
UNITE.
WARNING: DO NOT ADD ANY MATERIAL TO THE APPLIANCE, WHICH WILL COME IN
CONTACT WITH THE FLAMES, OTHER THAN THAT SUPPLIED BY THE MANUFACTURER
WITH THE APPLIANCE.
AVERTISSEMENT : N'AJOUTEZ PAS A CET APPAREIL AUCUN MATERIAU DEVANT
ENTRER EN CONTACT AVEC LES FLAMMES AUTRE QUE CELUI QUI EST FOURNI AVEC
CET APPAREIL PAR LE FABRICANT.
ELECTRICAL RATING / CLASS.: 115V 1.5AMP 60HZ
THE APPLIANCE MUST BE VENTED USING THE APPROPRIATE WOLF STEEL VENT KITS.
SEE OWNERS INSTALLATION MANUAL FOR VENTING SPECIFICS. PROPER
REINSTALLATION AND RESEALING IS NECESSARY AFTER SERVICING THE VENTAIR
INTAKE SYSTEM.
L'APPAREIL DOIT EVACUER SES GAZ EN UTILISANT L'ENSEMBLE D'EVACUATION
PROPRE A WOLF STEEL. REFERER AU MANUEL D'INSTALLATION DE PROPRIETAIRE
POUR L'EVACUATION PRECISE. IL EST IMPORTANT DE BIEN REINSTALLER ET
RESCELLER L'EVENT APRES AVOIR ASSURE LE MAINTIEN DU SYSTEME DE PRISE D'AIR.
WARNING: FOR INSTALLATION INTO A VENTED NON-COMBUSTIBLE FIREPLACE
ONLY. THE MINIMUM FIREPLACE SIZE IS: HEIGHT 21”, DEPTH 16”, WIDTH 32”. THE
MINIMUM INSIDE FLUE SIZE IS 7”. THE MINIMUM DISTANCE, FROM THE BOTTOM OF A
COMBUSTIBLE MANTLE PROJECTING A MAXIMUM 3” FROM THE WALL TO THE TOP OF
THE STANDARD TRIM IS 12”. SEE OWNERS MANUAL FOR GREATER EXTENSIONS.
A HEARTH MUST PROTRUDE A MINIMUM OF 12” FROM THE UNIT.
ATTENTION : POUR INSTALLATION DANS UN FOYER VENTILE EN MACONNERIE.
LES DIMENSIONS MINIMUMS SONT: HAUTEUR 21”, PROFONDEUR 16”, LARGEUR 32”. LE
DIAMETRE INTERIEUR MINIMUM DE CONDUIT D’EVACUATION EST DE 7”.
LA DISTANCE MINIMALE, DU BAS DU MANTEAU COMBUSTIBLE FORMANT UNE
PROJECTION MAXIMALE DE 3” DU MUR AU DESSUS DE LA GARNITURE NORMALE EST
12”. REFERER AU MANUEL D’INSTALLATION POUR DES EXTENSIONS PLUS GRANDES.
UNE DALLE DE PROTECTION INCOMBUSTIBLE DOIT SE PROLONGER D’AU MOINS 12" DE
L’UNITÉ.
NOT FOR USE WITH SOLID FUEL / UN COMBUSTIBLE
SOLIDE NE DOIT PAS ETRE UTILSE AVEC CET APPAREIL
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA
9700539 (WSL)
4001657 (NGZ)
4001658 (NAC)
4001659 (WUSA)
CERTIFIED UNDER: CSA 2.22b-2009, ANSI
Z21.50b-2009 VENTED GAS FIREPLACE.
HOMOLOGUE SELON LES NORMES: CSA
2.22b-2009, ANSI Z21.50b-2009 FOYER
GAZ AVEC EVACUATION.
SAMPLE
SAMPLE
BLE
LE
RENT
ENT
DA OR IN
DA OR IN
ETY
TY
PPLICABLE
PLICABLE
HOME
OME
ER, UNE SALLE DE
LE DE
E MAISON MOBILE SI
SI
ME CAN/CSA Z240MH
UR AU CANADA OU AUX
UR AU
UCTION DE MAISONS
UCTION DE
S LE CAS OU CETTE NORME
LE CAS OU CET
RER A LA NORME RELATIVE AU
LA NORME RELATIVE AU
NCENDIE POUR LES INSTALLATIONS
ENDIE POUR LES INSTALLATIONS
ES ET LES COMMUNAUTES, ANSI/NFPA
ES ET LES COMMUNAUTES, ANSI/NFPA
LENGTHS ARE 7 FEET AND 40 FEET
LENGTHS ARE 7 FEET AND 40 FEET
TICALES MINIMALES ET MAXIMALES SONT
ICALES MINIMALES ET MAXIMALES SONT
NT.
T.
S W.C. (NG) / 10 INCHES W.C.(LP)
W.C. (NG) / 10 INCHES W.C
3.5" D'UNE COLONNE D'EAU(GN) / 10" D'UNE
.5" D'UNE COLONNE D'EAU(
4.5" W.C.(NG) / 11" W.C. (LP)
.5" W.C.(NG) / 11" W.C. (LP)
TION MIN :
ION MIN :
4.5" D'UNE COLONNE D'EAU (GN
4.5" D'UNE COLONNE D'EAU
SSURE: 7" W.C. (NG) / 13" W.C. (LP)
7" W.C. (NG) / 13" W.C. (LP)
MENTATION MAX :
MENTATION MAX :
7" D'UNE COLONNE D'EA
7" D'UNE COLONNE D'E
EAU (P)
AU (P)
WITH GLASS DOORS CERTIFIED WITH THIS
TH GLASS DOORS CERTIFIED WITH THIS
R AVEC LES PORTES VITREES HOMOLOGUE
AVEC LES PORTES VITREES HOMOLOGU
.
RNING: DO NOT ADD ANY MATERIAL TO TH
NOT ADD ANY MATERIAL TO T
CONTACT WITH THE FLAMES, OTHER THAN
ONTACT WITH THE FLAMES, OTHER THAN
WITH THE APPLIANCE.
WITH THE APPLIANCE.
AVERTISSEMENT :
AVERTISSEM
N'AJOUTEZ PAS A C
OUTEZ PAS
ENTRER EN CONTACT AVEC LES FLA
ENTRER EN CONTACT AVEC LES FL
CET APPAREIL PAR LE FABRICANT
CET APPAREIL PAR LE FABRICAN
ELECTRICAL RATING / CLASS.:
ELECTRICAL RATING / CLASS
THE APPLIANCE MUST BE VE
THE APPLIANCE MUST BE V
SEE OWNERS INSTALLATI
SEE OWNERS INSTALLAT
REINSTALLATION AND R
REINSTALLATION AND
INTAKE SYSTEM.
NTAKE SYSTE
L'APPAREIL DOIT E
APPAREIL D
PROPRE A WOL
OPRE A WO
POUR L'EVAC
POUR L'EVAC
RESCELLE
RESCELLE
WARNIN
WA
ONLY
ON
MIN
M
C
INSTALLER: It is your responsibility to check off
the appropriate box on the rating plate according
to the model, venting and gas type of the
appliance.
For rating plate location, see “INSTALLATION
OVERVIEW” section.
This illustration is for reference only. Refer to the
rating plate on the appliance for accurate information.