Napoleon Fireplaces GDI44 Manuel d'utilisation
Page 18

18
W415-0734 / D / 02.03.12
7.4 FLAME
CHARACTERISTICS
7.3 VENTURI
ADJUSTMENT
This appliance has an air shutter that has been factory set open according
to the chart below:
Regardless of venturi orientation, closing the air shutter will cause a more
yellow flame, but can lead to carboning. Opening the air shutter will cause a
more blue flame, but can cause flame lifting from the burner ports. The
flame may not appear yellow immediately; allow 15 to 30 minutes for the
final flame colour to be established.
AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY A QUALIFIED
INSTALLER!
AIR
SHUTTER
OPENING
VENTURI
BURNER
ORIFICE
49.1
It’s important to periodically perform a visual check of the pilot and
burner fl ames. Compare them to the illustrations provided. If any fl ames
appear abnormal call a service person.
54.2
3/8” - 1/2”
FLAME MUST
ENVELOP UPPER
3/8" TO 1/2" OF
THERMOCOUPLE &
THERMOPILE
3"/ 3" LINER SYSTEM
FRONT REAR
NG
1/16"
3/16"
LP
3/16"
7/16"
AIR SHUTTER SETTING
2"/ 3" LINER SYSTEM
FRONT REAR
NG
1/8"
1/4"
LP
1/4"
5/8"
AIR SHUTTER SETTING
This appliance is approved for use with a 2" liner for air intake and a 3" liner for exhaust. For best performance,
however, it is recommended to use two 3" liners.
Air shutter settings will differ depending on the liner system used. Use the charts below to determine the
correct air shutter setting: