seCtIOn 3 |

Description, Features & Cooling

Description

These chargers are used to charge Lead
Acid Batteries (Flooded, AGM or Gel Cell).
SEC-1215UL (Maximum charging current
15A) and SEC-1230UL (Maximum charg-
ing current 30A) are used to charge 12 V
batteries. SEC-2415UL (Maximum charging
current 15A) is used to charge 24 V batter-
ies. These chargers can be powered from
AC power source of either 120 V,
60 Hz (Pre-set) or 230 V, 50 Hz (By
changing jumper position inside the
unit - See page 10 for instructions).

Features

• State of the art switched mode technol-

ogy is used for very high efficiency,
lightweight and quiet operation.

• User selectable AC input voltage -

120 V , 60 Hz (Pre-set) or 230 V , 50 Hz
(by changing jumper position inside the
unit (See page 10 for instructions).

• User selectable 2 or 3 stage charging

algorithm ensures rapid and safe charg-
ing of all types of lead acid batteries
- Flooded, AGM, Gel Cell or batteries
with external load. (Through externally
accessible DIP Switch - see pages 11 for
instructions)

• Fully automatic "Connect and Forget"

operation

• 3 banks of batteries can be charged

simultaneously without use of an
external battery isolator

• Monitoring through ON status LED

and Ammeter

• Temperature controlled cooling fan

(SEC-1230UL, SEC-2415UL)

• Protections against short circuit, over

current, reverse battery connection and
over temperature (over temperature for
SEC-1230UL and SEC-2415UL)

• Can be used as a power supply or as

a DC UPS (Uninterruptible DC Power
Supply) when used with a battery (DIP
Switch set at "Battery with load")

cooling

SEC-1215UL is cooled by convection and
does not have any thermal overload
shut down.

SeC-1230UL and SeC-2415UL are cooled by
convection and in addition, have a tem-
perature controlled fan for forced air cool-
ing. Two temperature sensors mounted on
the power transformer control the switch-
ing of the fan and over temperature shut
down. The fan will be switched on by the
first temperature sensor when the power
transformer reaches 70°C.

Hence, at lower loads, the fan may not
cut in and will be off. this is normal
.

In case the fan fails or if the cooling is not
adequate, the second temperature sen-
sor will shut down the unit if the power
transformer reaches 100°C. The red LED
will switch off. The unit will automatically
recover on removal of thermal overload
condition.