Display – Samlex America SSW-R1-12B Manuel d'utilisation

Page 6

Advertising
background image

6

3

DISPLAY

• All the 14 bars will be displayed momentarily during booting process when the remote is

switched on. After completion of booting process, the actual power level will be displayed
by the appropriate number of bars

• When the inverter is supplying no power (is in no load condition) or lower power below the

minimum power display threshold of 50W to 100W, bar graph will not be displayed. Also,
the back-light will be dim

• When the power supplied is more than the minimum power display threshold of 50W to

100W, the 1st bar will appear and the back-light will brighten. More number of bars will be
displayed proportional to power output level.

INPUT FAULT (3)

noTe: This message will be displayed momentarily (will be steady) during the boot
process when the remote is switched on. The message will flash during the actual
output fault condition

This message flashes when the inverter has shut down due to the following

(Please read the inverter manual for causes and remedies):

• DC input voltage at the terminals of the inverter is low: 10.5 +/- 0.3V VDC or lower
• DC input voltage at the inverter terminals is high: 15.3 +/- 0.3V VDC or higher
• over temperature

OUTPUT FAULT (4)

noTe: This message will be displayed momentarily (will be steady) during the boot
process when the remote is switched on. The message will flash during the actual
output fault condition

This message flashes when the inverter shuts down due to over load or short

circuit on the AC output side (Please read the inverter manual for causes and

remedies):

Display when GFCI has tripped due to leakage on the Load Side

(output side)

The AC output power of the inverter is fed through a Duplex neMA5-20 outlet

with GfCI protection.

A GfCI has a relay operated mechanical switch that mechanically switches off

the Load Side (output side) of the GfCI from its Line Side (input side) in case of a