4

5

3

DISPLAY

A Green backlit LCD display is used to display operational parameters and fault

conditions. Details of information displayed are shown at fig 3.1 below:

INPUT VOLTAGE (1)

Input voltage is displayed using 3-digit, 7-segment numerals with 1 decimal:

• Displays 88.8 momentarily during booting process when the remote is switched on. After

completion of booting, the actual value will be displayed

• Please note that the displayed voltage will be lower than the voltage at the battery

terminals by the amount of voltage drop in the DC side input wires.

OUTPUT POWER (2)

output power is displayed by a bar graph consisting of 14 gradually increasing

bars for depicting increasing output power level.

Fig. 3.1 Details of LCD Screen

1

2

3

4

The backlighting has 2 intensities
of brightness – dim and bright:
• When the inverter is supplying no

power (is in no load condition) or
lower power below the minimum
power display threshold of 50 W
to 100W, the bar graph will NOT
be displayed. Also, the back-light
will be dim

• When the power supplied is

more than the minimum power
display threshold of 50W to
100W, the 1st bar will appear
and the back-light will brighten.
More number of bars will be
displayed proportional to power
output level.