STEINEL IS D360-24 Manuel d'utilisation
Page 8

www.steinel.net
(800) 852-4343
www.steinel.net
(800) 852-4343
Troubleshooting
No power at the
sensor
Lights do not
switch ON
breaker has tripped or
is not switched ON
break in wiring
short circuit
light level setting is in
nighttime mode during
daytime operation
lamp burned out
power is off
breaker has tripped
detection zone not
correctly adjusted
reset breaker, check
wiring with voltage
tester
check for proper
wiring connections
adjust light level
setting
replace lamp
turn power on at
circuit breaker
reset breaker
readjust
Problem
Cause
Remedy
14
Troubleshooting
Lights do not
switch OFF
Lights keep
switching ON/OFF
Lights switch ON
without obvious
movement
power pack is in
manual on mode when
being used with a line
voltage switch
abundant heat from the
fixture’s lamps is within
the detection zone and
keeps lights on as a
result of temperature
change
continuous movement
in the detection zone
switched on light is
within detection zone
low voltage overload
on power pack
sensor is detecting
movement outside of
the lighting zone
place power pack in
the auto on mode
mount sensor below
the lamps `
readjust zone or
apply shroud
adjust detection
zone or apply
shrouds
reduce the
number of devices
connected to the
power pack
adjust zone or apply
shrouds
Problem
Cause
Remedy
15