STEINEL IS D360-24 Manuel d'utilisation

Page 2

Advertising
background image

www.steinel.net

(800) 852-4343

www.steinel.net

(800) 852-4343

In this package

• IS D360-24 occupancy sensor

(switching module and sensor
module)

• Masking shrouds
• Fitting frame and securing

spring

• Installation instructions

Installation Overview

WARNING

• Turn power off at the circuit breaker before installing the sensor
• Sensor must be installed and used in accordance with appropriate

electrical codes and regulations

• Installation by a qualified electrician is recommended

2

Intended uses

• The sensor mounts to the

ceiling for the automatic
switching of lights

Needed for installation

• 2-7/8 Inch, (73mm) hole saw
• Wire nuts
• 3 conductor 18AWG wire
• Steinel TR 100 or TR 150

power pack

Applications

• Recessed ceiling mount in

office, conference rooms,
vestibules, and break rooms

• Can be used in a plenum

Product Overview

24 VDC

PIR

IP20

Product description

The STEINEL IS D360-24 is a
highly accurate ceiling mount
occupancy sensor for indoor use.

3

The sensors use passive infrared
(PIR) technology to turn lighting
ON and off based on occupancy.

Advertising