PUSH SIDE, PARALLEL ARM MOUNTED ON:
1260-18PA DROP PLATE
GENERAL NOTES:
1.
2. CLOSER SIZE
.
3. TOP RAIL LESS THAN 4 3/4 REQUIRES DROP PLATE.
4. ALL DIMENSIONS APPLICABLE FOR HOLD OPEN OR DEAD STOP.
5. DELAYED ACTION OPTIONAL.
6. REINFORCING PER. ANSI/SDI-100 RECOMMENDED FOR HOLLOW
METAL DOOR AND FRAMES.
IF DOOR IS HUNG ON PIVOTS OR SWING CLEAR HINGES LOCATE CLOSER AND SHOE
FROM CENTER LINE OF PIVOT POINT.
10” x 2 1/4” x 2 7/8”
1260 CUSH
DROP PLATES
PAGE 4
®
1-800-526-2400
LEFT HAND DOOR SHOWN
RIGHT HAND DOOR OPPOSITE
1260-18PA
3 3/16
1 11/16
81 mm
43 mm
1 1/16
27 mm
5/16
8 mm
10 1/4
260 mm
11 3/8
283 mm
12
305 mm
= 85°
= 90°
= 100°
CL
2 3/8
60 mm
11/16
17 mm
9 1/2
241 mm
= 110°
4 5/8
117 mm
5 3/4
146 mm
6 3/8
162 mm
= 85°
= 90°
= 100°
3 7/8
98 mm
= 110°
32 mm
1 1/4
8 mm
5/16
5 1/8
130 mm
7 7/8
200mm
1 3/8
35 mm
NOTES -
1. MINIMUM TOP RAIL 2 ½”.
L
C
L
C