Electrical diagrams, K924-5 remote control (optional), G-19 – Lincoln Electric CLASSIC SVM194-A Manuel d'utilisation
Page 225

ELECTRICAL DIAGRAMS
G-19
CLASSIC® 300D & 300G
SCHEMATIC - COMPLETE MACHINE - (CODES 11413, 11414) (L13097)
OIL PRESSURE SWITCH / SENDER
TEMPERATURE SWITCH / SENDER
W
G
TEMPERATURE
GAUGE
S
I
G
OIL PRESSURE
GAUGE
S
I
G
AMMETER
+
-
ENGINE CONTROL UNIT (ECU)
1
ENGINE
PROTECTION
LIGHT
ALTERNATOR
WK
G
NEGATIVE OUTPUT
TERMINAL
POSITIVE OUTPUT
TERMINAL
4
3
2
1
GENERATOR LEAD BLOCK
SHOWN AS VIEWED WITH
ENGINE IN THIS DIRECTION
-
-
+
+
INTERPOLE
COILS
SHUNT
FIELD
SERIES FIELD
TYPICAL CURRENT
DRAW IS 40 AMPS
+
HOUR METER
12 11 10 9 8 7 6 5 4 3 2 1
P10
J5
SWITCH CLOSES
AT 6+/-2 PSI
SENDER OPERATION:
0 PSI -> 10+/-5 OHMS
40PSI -> 105+/-5 OHMS
80 PSI -> 187+/-5 OHMS
FJW-5AP
COIL PAIR:
25.2 - 26.7
OHMS EACH
FLYBACK DIODE PREVENTS
VOLTAGE SPIKES IN SHUNT FIELD
FROM DAMAGING LOCAL/REMOTE
TOGGLE SWITCH WHEN SWITCHED
SHOWN IN LOCAL
POSITION
3 TURNS
2 TURNS
SENSOR GROUNDS LEAD
ON SENSE OF WELD OR
AUXILIARY LOAD
Y
RHEOSTAT
W
G
X
REMOTE
RECEPTACLE
LOCAL / REMOTE
SWITCH
SWITCH CLOSES
AT 230v+/-6vF
SENDER OPERATION:
140vF -> 134+/-13.5 OHMS
194vF -> 51.2+/-4.3 OHMS
212vF -> 38.5+/-3 OHMS
P9
J8
4
6
5 3
1
2
64+/-6.4 OHMS MAX
WITH AC AUXILIARY POWER,
ROUTING DIRECTIONS OF THESE
LEADS DOES NOT MATTER
BRUSH POSITION SHOWN AS
VIEWED FROM CONTROL PANEL
+
_
COLOR: RED
12 VOLT
NORMALLY OFF
SHOWN IN "OFF"
POSITION
53
51C
50
50A
51
51A
212D
43
200
54
44
212A
212B
61
844A
841
844
N
U
67A
602B
602
SELECTOR SWITCH
90-MIN
130-80
190-120
240-160
220-MAX
WELDING
GENERATOR
CCW
-40 TO 40 AMPS
AMMETER SHOWS FULL
DISCHARGE WHILE PRESSING
GLOW PLUG SWITCH
40 AMP / 12 VOLT
IG
B
L
GLOW PLUGS
12.6 VOLTS MIN
AT REST
14-14.5 VOLTS
WHILE RUNNING
BACK, BOTTOM
OFMACHINE
JUMPER PLUG IS FOR CONNECTION
TO WIRE FEED MODULE
LOCATEDBEHINDUPPERPORTIONOFCONTROLPANEL
LOCATEDBEHINDUPPERLEFT
PORTIONOFCONTROLPANEL
TYPICAL OCV (WARM MACHINE):
94-99.0 VOLTS AT MAX RHEOSTAT
44-54.5 VOLTS AT MIN RHEOSTAT
DRIVER
CIRCUITS
JUMPERPLUGISWIRE-TIEDUP
BEHINDLOCAL/ REMOTESWITCHON
RIGHTSIDEOFMACHINE(ASVIEWED
FROMCONTROLPANEL)
SENDER IS APPROX.
500 OHMS AT 70vF
1
2
3
WATER
TEMP.
SENSOR
ENGINE
SPEED
SENSOR
31
60F
19
58
6
IGNITION
SWITCH
212C
12
START
BUTTON
7
52A
52B
55
62
STARTER
RELAY
RELAY CONTACTS FOR 52 AND 52A ARE NORMALLY
OPEN. THE STARTER MOTOR CAN ONLY BE ENGAGED
WHEN THE IGNITION SWITCH IS "ON" AND THE ECU
SENSES LESS THAN 700 RPM. IF THE ENGINE IS SHUT
DOWN DUE TO A FAULT
(EVEN IF THAT CONDITION
DOES NOT RESULT IN A FLASH CODE, SUCH AS RUNNING
OUT OF FUEL),
THE IGNITION SWITCH WILL NEED TO BE
TURNED OFF THEN BACK ON TO RESTART THE ENGINE.
4
87
86
88
11
2
3
10,000 +/- 1,000 OHMS MAX
TURN POT COUNTERCLOCKWISE TO
REDUCE RESISTANCE AND SUBSEQUENTLY
REDUCE RPM BY UP TO 150RPM
RATED VOLTAGE: 12V
RATED CURRENT: 22mA MAX
60
SENSOR OPERATION:
-4vF -> 18.80 kOHMS
104vF -> 1.14 kOHMS
212vF -> .16 kOHMS
RATED VOLTAGE: 12V
RATED CURRENT: 4.5A(MAX.)-TERMINAL #15
LEAKAGE CURRENT 10micro A (MAX.)-TERMINAL #16
57
34
RATED VOLTAGE: 12V
RATED CURRENT: 2A
COIL RESISTENCE:
2.8 +/- .28 OHMS AT 20vC
ENERGIZED FOR RUN
DE-ENERGIZED FOR STOP
ACTUATOR CONTROLS RPM
MECHANICAL STOP WILL SHUT
DOWN THE ENGINE AT 115%
OF RATED SPEED.
27
28
841A
9
212E
26
64
16
15
51B
70A
70B
CONNECT TO
GROUND FOR
800RPM
CONNECT TO
GROUND FOR
1600RPM, LEAVE
UNCONNECTED
FOR 1800RPM
30
32
610A
+
-
+
-
215
810
820
SLIP RINGS
214
AC
AC
48
GND-T
11C
21
EXCITER STATOR
(ALTERNATOR)
11B
POSITIVE SLIP RING
IS NEAREST TO IRON
EXCITER REVOLVING
FIELD (ROTOR)
400E
400D
15A
610
610
600B
600A
42
600
41
602A
67B
60E
INTERPOLE
COILS
ACTUATOR
56
18
69
13
60A
94
20
93
17
CCW
RPM CONTROL POTENTIOMETER
WIRE-TIEDTOHARNESS
BEHINDCONTROLPANEL
FUSE
BOTHOPENLEADSAREWIRE-TIEDINSIDETHEHARNESSBEHINDCONTROLPANEL
SHOWN IN "AUTO
IDLE" POSITION
IDLER SWITCH
GND-B
841B
WINDING SPEC: ALT-241-3A
40.5 - 42.5 OHMS AT 25C
EXCITER CIRCUIT
LEAD 21A TO 21B
WINDING SPEC: ALT-214-2B
.488 OHMS MAX AT 25C
115 VOLT CIRCUIT
LEAD 810 TO 820
WINDING SPEC: ALT-214-2C
.230 OHMS MAX AT 25C
115 VOLT CIRCUIT
LEAD 820 TO 830
WINDING SPEC: ALT-214-2D
.424 OHMS MAX AT 25C
LIGHT CODE
FAILURE DETECTED
POSSIBLE CAUSE - CORRECTIVE MEASURE
LONG 1, SHORT 1 RPM IS OVER 115% OF RATED RPM (2070 RPM)
ACTUATOR IS STUCK - REMOVE ACTUATOR AND VERIFY PLUNGER PULLS IN WHEN ENERGIZED
LOW OIL - CHECK OIL LEVEL ON DIPSTICK
FAULTY OIL PRESSURE SWITCH - CHECK THAT "WK" STUD IS OPEN WHEN ENGINE IS RUNNING
LEAD TO OIL PRESSURE SWITCH "WK" STUD MAY BE GROUNDED - CHECK
BROKEN OR LOOSE BELT - INSPECT
LEAD TO "L" TERMINAL ON ALTERNATOR MAY BE SHORTED TO GROUND - CHECK
FAULTY ALTERNATOR - CHECK
AMOUNT OR QUALITY OF COOLANT INCORRECT - CHECK
FAULTY WATER TEMPERATURE SWITCH - CHECK THAT "WK" STUD IS OPEN WHEN ENGINE IS NOT RUNNING
LEAD TO WATER TEMPERATURE SWITCH MAY BE GROUNDED - CHECK
LONG 1, SHORT 5
FAULTY RPM SENSOR - CHECK FOR GOOD CONNECTION
FAULTY ECU - CHECK FOR 12 VOLTS ON SUPPLY LEAD TO RPM SENSOR FROM ECU
FAULTY ACTUATOR - CHECK FOR PROPER COIL RESISTANCE
LEADS TO ACTUATOR MAY BE OPEN OR GROUNDED - CHECK
LONG 2, SHORT3
FAULTY WATER TEMPERATURE SENSOR - CHECK FOR PROPER RESISTANCE
LEAD TO WATER TEMPERATURE SENSOR MAY BE OPEN - CHECK FOR CONTINUITY
FAULTY WATER TEMPERATURE SENSOR - CHECK FOR PROPER RESISTANCE
LEAD TO WATER TEMPERATURE SENSOR MAY BE GROUNDED - CHECK
LEAD TO "L" TERMINAL ON ALTERNATOR MAY BE OPEN - CHECK FOR CONTINUITY
BROKEN OR LOOSE BELT - INSPECT
FAULTY ALTERNATOR - CHECK
INCORRECT BATTERY - INSPECT
FAULTY ALTERNATOR - CHECK
LONG 2, SHORT 8
LESS THAN 4 VOLTS TO RPM SENSOR AND/OR
ACTUATOR SENSED BY ECU
FAULTY ECU - CHECK FOR 12 VOLTS ON LEADS TO RPM SENSOR AND ACTUATOR FROM ECU
NOT ENABLED FOR LINCOLN PRODUCTS
NOT ENABLED FOR LINCOLN PRODUCTS
0 RPM IS DETECTED AND 12V IS DETECTED
FROM "L" TERMINAL ON ALTERNATOR
LONG 2, SHORT 1
LONG 1, SHORT 4
HIGH WATER TEMPERATURE DETECTED FOR 1
SECOND
LONG 1, SHORT 2 LOW OIL PRESSURE DETECTED FOR 1 SECOND
LONG 1, SHORT 3
"L" TERMINAL IS GROUNDED ON ALTERNATOR
FOR 1 SECOND
LONG 2, SHORT 7 OVER 18 VOLTS DETECTED FROM ALTERNATOR
CURRENT TO ACTUATOR IS OUT OF LIMIT
LONG 2, SHORT 2
LONG 2, SHORT 6
0 VOLTS DETECTED FROM "L" TERMINAL ON
ALTERNATOR FOR 1 SECOND
LONG 2, SHORT 5 150C WATER TEMPERATURE DETECTED
-50C WATER TEMPERATURE DETECTED
LONG 2, SHORT4
12 VOLT SUPPLY
THE ECU WILL INDICATE FAULT CONDITIONS BY FLASHING THE ENGINE
PROTECTION LIGHT IN A CODED SEQUENCE, SEE CHART FOR FAULT
CODES AND CORRECTIVE MEASURES. WHEN THE ENGINE IS SHUT
DOWN DUE TO A FAULT, THE IGNITION SWITCH WILL NEED TO BE
TURNED OFF THEN BACK ON TO RESTART THE ENGINE.
12 VOLT SUPPLY
N
U
GLOW PLUG
BUTTON
+
BATTERY
STARTER
MOTOR
STARTER
SOLENOID
842
42
W
W
Y
Y
MOUNTEDTONEGATIVE
BRUSHHOLDER
THIS CIRCUIT USES THE
RESIDUAL MAGNETISM OF
THE GENERATOR TO FLASH
THE EXCITE THE ROTOR
WHICH IN TURN PROVIDES
THE EXCITATION FOR THE
GENERATOR
DIODE AND MOV ASSEMBLY
IN-LINE BOLTED CONNECTION
BEHIND CONTROL PANEL
600C
BACK, LEFTSIDEOFENGINE
FRONT, LEFTSIDEOFENGINE
BACK, LEFTSIDEOFENGINE
JUMPERPLUGISBEHINDLOWER
RIGHTSIDEOFCONTROLPANEL
LOWER, RIGHTSIDEOFCONTROLPANEL
DIODE
LOWER,
RIGHTOF
CONTROL
PANEL
LOWERLEFTOF
CONTROLPANEL
LOWERLEFTOF
CONTROLPANEL
CENTEROF
CONTROLPANEL
BACK, RIGHT
SIDEOFENGINE
BACK, LEFT
SIDEOFENGINE
BACK, RIGHT
SIDEOFENGINE
CENTEROF
CONTROLPANEL
UNDERLEFTDOOR
LOWERRIGHTOFCONTROLPANEL
44
28
12 VOLT
SUPPLY
ECU CONNECTOR DETAIL
9
17
25
34
26
18
10
1
FLASHES ALTERNATOR
SENSES ALTERNATOR OUTPUT
THE P10 PLUG IS ONLY ON UNITS
WITHOUT THE WIRE FEED MODULE.
THE WIRE FEED MODULE HAS A
HARNESS THAT PLUGS DIRECTLY
INTO J5.
41
JUMPERPLUGIS
WIRE-TIEDUP
BEHINDLOCAL/
REMOTESWITCH
ONRIGHTSIDEOF
MACHINE
SCHEMATIC S25973
CURRENT SENSING PC BOARD
602B
400F
WHITE LOAD
WHITE LINE
HOT LOAD
HOT LINE
115 VOLT GFCI
RECEPTACLE
400D
CB2
15A
6A
810
230 VOLT
RECEPTACLE
7A
6A
GND-E
11A
CB1
20A
820
GND-S
K924-5 REMOTE CONTROL
(OPTIONAL)
RHEOSTAT
REMOTE CONTROL BOX
25+/-1.25 OHMS EACH
64+/-6.4 OHMS MAX
CCW
Y
W
G
X
REMOTE CONTROL PLUG
L13097
CLASSIC 300D (KUBOTA V2203M)
MACHINE SCHEMATIC
NONE
L12265
Maglietta
D. BENDER
UNLESS OTHERWISE SPECIFIED TOLERANCE
MANUFACTURING TOLERANCE PER E2056
ON 2 PLACE DECIMALS IS ± .02
ON 3 PLACE DECIMALS IS ± .002
ON ALL ANGLES IS ± .5 OF A DEGREE
WITH PUBLISHED STANDARDS.
MATERIAL TOLERANCE (" ") TO AGREE
t
DO NOT SCALE THIS DRAWING
DRAWN BY:
DESIGN INFORMATION
ENGINEER:
APPROVED:
REFERENCE:
EQUIPMENT TYPE:
SUBJECT:
SCALE:
MATERIAL
DISPOSITION:
APPROVAL
DATE:
PROJECT
NUMBER:
UF
CRM37535
1
PAGE ___ OF ___
1
ENGINEERING CONTROLLED
MANUFACTURER:
No
DOCUMENT
NUMBER:
DOCUMENT
REVISION:
THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OWNED BY LINCOLN GLOBAL, INC. AND MAY NOT BE DUPLICATED, COMMUNICATED
TO OTHER PARTIES OR USED FOR ANY PURPOSE WITHOUT THE EXPRESS WRITTEN PERMISSION OF LINCOLN GLOBAL, INC.
PROPRIETARY & CONFIDENTIAL:
B
04/13/2007
REVISED 115 VOLT GFCI RECEPTACLE GRAPHICS
CHANGE DETAIL:
L1309
7
LEAD COLOR CODE:
B-BLACK OR GRAY
G-GREEN
R-RED OR PINK
U-BLUE
W-WHITE
Y-YELLOW
N-BROWN
COMPONENT VALUE UNITS:
CAPACITOR: MFD/VOLTS
RESISTOR: OHMS/WATTS
CONNECTOR PIN NUMBERS:
VIEW OF CONNECTOR ON PC BOARD
1 2
6
7
12
LATCH
EX. 12 PIN CONNECTOR
LABELS:
COMMON
FRAME GROUND
EARTH GROUND
G-19
NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual.