ALTERNATOR STATOR REMOVAL AND REPLACEMENT (continued)
TROUBLESHOOTING AND REPAIR
F-71
F-71
CLASSIC® 300D & 300G
FIGURE F.8 - LEAD DISCONNECTION POINTS
YELLOW AND WHITE WIRE
IN-LINE CONNECTORS;
YELLOW LEADS; BLACK
CURRENT TRANSFORMER
LEAD
ALL LOCATED BEHIND
CASE FRONT
FIGURE F.9- LEAD DISCONNECTION – CIRCUIT BREAKER, RECEPTACLES, FIELD BRIDGE RECTIFIER
230 VAC RECEPTACLE
CB1 CIRCUIT BREAKER
115 VAC RECEPTACLE
CB4 CIRCUIT BREAKER
FIELD FUSE HOLDER
FIELD RECTIFIER BRIDGE