TROUBLESHOOTING AND REPAIR
F-66
F-66
CLASSIC® 300D & 300G
ALTERNATOR ROTOR REMOVAL
AND REPLACEMENT PROCEDURE (continued)
FIGURE F.6 – ROTOR REMOVAL
STATOR
FRAME
NUT
SLEEVE
COLLAR
"BENT"
WASHER
BRUSH
HOLDER
ASSEMBLY
See Figure F.6 for steps 6 - 8.
6. With the 7/16" wrench, remove the two bolts,
nuts and washers mounting the brush holder
assembly to the stator frame.
7. Bend the flat washer away from the rotor lock-
ing nut.
8. With the 1-5/8" socket wrench, remove the
rotor locking nut, washer and sleeve collar.
NOTE: The sleeve collar will have to be
removed with a gear puller. Be careful
not to damage the rotor slip ring assem-
bly. Remove the rotor by pulling it free of
the generator shaft.