3.
Remove the three 10-32 hex nuts from the terminal posts.
A
C
B
A.
10-32 hex nuts
B.
Terminal Posts
C.
Ground-link strap
4.
Add strain relief.
Style 1: Power supply cord strain relief
�
Remove the knockout for the power supply cord.
�
Assemble a UL listed strain relief in the opening.
A
A.
UL listed strain relief
�
Tighten strain relief screw against the power supply cord.
Style 2: Direct wire strain relief
�
Remove the knockout as needed for the flexible conduit
connection.
�
Assemble a UL listed conduit connector in the opening.
A
B
A.
Removable retaining nut
B.
Conduit
�
Tighten strain relief screw against the flexible conduit.
5.
Complete installation following instructions for your type of
electrical connection: