3.

Remove the three 10-32 hex nuts from the terminal posts.

A

C

B

A.

10-32 hex nuts

B.

Terminal Posts

C.

Ground-link strap

4.

Add strain relief.

Style 1: Power supply cord strain relief

Remove the knockout for the power supply cord.

Assemble a UL listed strain relief in the opening.

A

A.

UL listed strain relief

Tighten strain relief screw against the power supply cord.

Style 2: Direct wire strain relief

Remove the knockout as needed for the flexible conduit
connection.

Assemble a UL listed conduit connector in the opening.

A

B

A.

Removable retaining nut

B.

Conduit

Tighten strain relief screw against the flexible conduit.

5.

Complete installation following instructions for your type of
electrical connection:

4-wire

(recommended)

3-wire

(if 4-wire is not available)