Installation requirements, Tipping radius, Water supply requirements – Dacor IF36RNBOL Manuel d'utilisation

Page 7: Side tipping radius, Water pressure

Advertising
background image

5

Installation Requirements

If the water pressure to the reverse osmosis system is less than

40 to 60 psi (276 to 414 kPa):

Check to see whether the sediment filter in the reverse

ƒ

osmosis system is blocked. Replace the filter if necessary.
Allow the storage tank on the reverse osmosis system to refill

ƒ

after heavy usage.
If your refrigerator has a water filter cartridge, it may further

ƒ

reduce the water pressure when used in conjunction with a

reverse osmosis system. Remove the water filter cartridge.

If you have questions about your water pressure, call a licensed,

qualified plumber.

Tipping Radius

Be sure there is adequate ceiling height to stand the refrigerator

upright when it is moved into place.

The dolly wheel height must be added to the tipping radius

ƒ

when a dolly is used.
If needed, the tipping radius can be reduced. See

ƒ

Reduce

Tipping Radius.

Side Tipping Radius

The side tipping radius varies depending upon the width of the

model.
NOTE: Tip on side only.

Water Supply Requirements

All installations must meet local plumbing code requirements.

ƒ

The water shutoff should be located in the base cabinet on

ƒ

either side of the refrigerator or some other easily accessible

area. The right-hand side is recommended. The access hole

through the cabinet must be within ½” (12.7 mm) of the rear

wall.

NOTE: If the water shut off valve is in the back wall behind the

refrigerator, it must be at an angle so that the tube is not kinked

when the refrigerator is pushed into its final position.

If the water shutoff valve is not in the cabinets, the plumbing

ƒ

for the water line can come through the floor. A ½” (12.7 mm)

hole for plumbing should be drilled at least 6” (15.2 cm) from

the right or left hand side cabinet or panel. On the floor, the

hole should be no more than 1” (2.54 cm) away from the back

wall. See Connect the Water Supply.
If additional tubing is needed, use copper tubing and check

ƒ

for leaks. Install the copper tubing only in areas where the

household temperatures will remain above freezing.
Do not use a piercing-type or ³⁄

ƒ

16

” (4.76 mm) saddle valve

which reduces water flow and clogs more easily.

NOTE: Your refrigerator dealer has a kit available with a ¼” (6.35

mm) saddle-type shutoff valve, a union and copper tubing. Before

purchasing, make sure a saddle-type valve complies with your

local plumbing codes.

Water Pressure

A cold water supply with water pressure between 30 and 120 psi

(207 and 827 kPa) is required to operate the water dispenser and

ice maker. If you have questions about your water pressure, call a

licensed, qualified plumber.

Reverse Osmosis Water Supply

IMPORTANT: The pressure of the water supply coming out of

a reverse osmosis system going to the water inlet valve of the

refrigerator needs to be between 30 and 120 psi (207 and 827

kPa). If a reverse osmosis water filtration system is connected

to your cold water supply, the water pressure to the reverse

osmosis system needs to be a minimum of 40 to 60 psi (276 to

414 kPa).

Possible water

line locations

Access hole within 1/2”

(12.7 mm) of floor and rear wall

1"

(2.54 cm)

6"

(15.2 cm)

6"

(15.2 cm)

A. Tip this side only

90

¹⁄

2

"

(229.9 cm)

A