Installation requirements, Electrical requirements, Location requirements (continued) – Dacor IF36RNBOL Manuel d'utilisation

Page 6: Warning, Recommended grounding method

Advertising
background image

4

Electrical Requirements

Before you move your refrigerator into its final location, it is

important to make sure you have the proper electrical connection.

Recommended Grounding Method

A 115 Volt, 60 Hz., AC only 15 or 20-amp fused, grounded

electrical supply is required. It is recommended that a separate

circuit serving only your refrigerator be provided. Use an outlet

that cannot be turned off by a switch. Do not use an extension

cord.
IMPORTANT: If this product is connected to a GFCI (Ground

Fault Circuit Interrupter) protected outlet, nuisance tripping of the

power supply may occur, resulting in loss of cooling. Food quality

and flavor may be affected. If nuisance tripping has occurred, and

if the condition of the food appears poor, dispose of it.
NOTE: Before performing any type of installation, cleaning, or

removing a light bulb, remove the top grille and turn the master

power switch to

OFF or disconnect power at the circuit breaker

box.
When you are finished, turn on the master power switch or

reconnect power at the circuit breaker box. Then reset the control

to the desired setting.

Installation Requirements

Location Requirements (continued)

A grounded 3 prong electrical outlet should be placed within

ƒ

4” (10.2 cm) of the right side cabinets or end panel. See

Electrical Requirements for more information.
The water shutoff should be located in the base cabinet on

ƒ

either side of the refrigerator or some other easily accessible

area. If the water shutoff valve is not in the cabinets, the

plumbing for the water line can come through the floor or

the back wall. See Water Supply Requirements for more

information.

NOTE: Flooring under refrigerator must be at same level as the

room. Face of cabinet must be plumb.

Electrical Shock Hazard

Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.

WARNING

4"

(10.2 cm)

83

¹/

2

" (212.1 cm) min.

84

³/

4

" (215 cm) max.

to bottom of solid soffit

24"

(60.96 cm) min.

77"

(196 cm)

35½”

(90.2 cm)

See page 5

Advertising
Ce manuel est liée aux produits suivants: