AIR CONDITIONER

Note: The exhaust hose must be properly vented (outdoors) during air conditioning mode.

1) Press the POWER SWITCH key (Fig. A) to switch on the unit, and the previous

set temperature will be shown in the temperature display area of the control panel.

2) Press the MODE key (Fig. B) until the COOL indicator light illuminates on the

control panel (Fig.C). Each depression of the MODE key will advance to a different

mode setting (Cool-Dehumidifier-Fan-Heat-Auto)

3) Press the appropriate increase

or decrease

buttons (Fig. D) to select a

suitable operating temperature setting. Temperature settings are adjustable between

16°C (61°F) to 32°C (89°F).

4) Press the FAN key (Fig. E) to select the desired fan speed setting (Auto-High-

Med.-Low). Your selection will appear on the control panel (each depression of the

fan key will advance to a different setting).

• Cooling stops automatically when the set temperature is achieved. Cooling resumes

when the room temperature rises above the “set” temperature level.

DEHUMIDIFIER

Note: During dehumidifier mode, the exhaust hose does not have to be vented outdoors.

1) Press the ON/OFF key pad to switch the unit on (Fig. A)

2) Press the MODE key (Fig. B) until the DRY indicator illuminates on the control

panel (Fig.G). Each press of the MODE key will advance to a different mode

setting (Cool-Dehumidifier-Fan-Heat-Auto).

3) If room temperature is >25°C (77°F), fan speed can be adjusted. Press the FAN key

(Fig. E) to select the desired FAN SPEED setting. Your selection will appear on the

control. Each depression of the fan key will advance to a different fan speed as

shown in Fig. F. Otherwise fan speed is fixed to “low”.

NOTE: The warm air exchange hoses must vent inside the room when using

Dehumidifier Mode, not outside as in Cooling Mode.

FAN

Note: During Fan Mode, the exhaust hose does not have to be vented outdoors.

1) Press the POWER SWITCH key to turn the unit on (Fig. A).

2) Press the MODE key (Fig. B) until the FAN indicator illuminates on the control

panel (Fig. H). Each press of the MODE key will advance to a different mode

setting (Cool-Dehumidifier-Fan-Heat-Auto).

3) Press the FAN Key (Fig. E) to select the desired FAN SPEED setting. Your

selection will appear on the control panel. Each press of the fan key will advance to

a different fan speed (High- Med- Low) as shown in Fig. F.

HEAT

Note: During Heat Mode, the exhaust hose does not have to be vented outdoors.

1) Press the POWER SWITCH key (Fig. A) to switch on the unit, and the previous set

temperature will be shown in the temperature display area of the control panel.

2) Press the MODE key (Fig. B) until the Heat indicator light illuminates on the control

panel (Fig. I). Each depression of the MODE key will advance to a different mode

setting (Cool- Dehumidifier- Fan- Heat).

3) Press the appropriate increase

or decrease

buttons (Fig D) to select a

suitable operating temperature setting. Temperature settings are adjustable between

16°C (61°F) to 27°C (80°F).

4) Press the FAN key (Fig. E) to select the desired fan speed setting (High- Med.-

Low). Your selection will appear on the control panel (each depression of the fan

key will advance to a different setting)

• Heating stops automatically when the set temperature is achieved. Heating resumes

when the room temperature rises above the “set” temperature level.

Fig. A

Fig. F

Fig. G

6

OPERATION (cont’d)

Fig. B

Fig. C

Fig. D

Fig. E

High

Medium

Low

Orange

Green

Fig. H

Yellow

Fig. I

Red