Electrical Specifications

1. All wiring must comply with local and national

electrical codes and be installed by a qualified
electrician. If you have any questions regarding
the following instructions, contact a qualified
electrician.

2. Check available power supply and resolve any

wiring problems BEFORE installation and
operation of this unit.

3. This appliance draws 11 nameplate amps under

Cooling Mode and may be used in any properly
wired, general purpose 15 amp household
grounded receptacle.

4. For your safety and protection, this unit is

grounded through the power cord plug when
plugged into a matching wall outlet. If you are
not sure whether the wall outlets in your home
are properly grounded, please consult a qualified
electrician. DO NOT USE PLUG ADAPTERS
OR EXTENSION CORDS WITH THIS UNIT.
If it is necessary to use an extension cord with
this unit, use an approved “air conditioner
extension cord only. (available at most local
hardware stores)

5. The manufacturers nameplate is located on the

rear panel of the unit and contains electrical and
other technical data specific to this unit.

6. To avoid the possibility of personal injury, always

disconnect the power supply to the unit, before
installing and/or servicing.

Power Supply Cord

The power cord supplied with this air conditioner
contains a device that senses damage to the power
cord. To test if your power cord is working properly,
you must do the following;

1 Connect the power supply cord to an electrical

outlet.

2. The power supply cord has two buttons located

on the head of the plug. One button is marked
‘TEST’, the other button is marked ‘RESET’.
Press the ‘TEST’ button, you will then hear a
click as the ‘RESET’ button pops out.

3. Press the ‘RESET’ button, you will hear a click

as the button engages.

4. The power supply cord is now energized and

supplying electricity to the air conditioner. (On
some products this is also indicated by a light on
the plug head).

Table 1

Suggested Individual Branch Circuit

Nameplate Amps

AWG Wire Size*

11

14

AWG- American Wire Gage

* Based on copper wire at 60°C temperature rating.

Table 2

Receptacle and Fuse Types

Rated Volts

125

Amps

15

Wall Outlet

Fuse Size

15

Time Delay Fuse

Plug Type

(or circuit breaker)

CAUTION

Do not leave this unit unattended in a space

where people or animals who cannot react to a

failed unit are located. A failed unit can cause

extreme overheating or death in such an

enclosed, unattended space.

3

The power cord supplied with this air conditioner
contains a current leakage detection device
designed to reduce the risk of fire. Please refer to
the section ‘Power Supply Cord’ for details. In the
event the power supply cord is damaged, it cannot
be repaired and must be replaced with a new cord
from the product manufacturer.

Under no circumstances should this device be
be used to turn the unit on or off.

The ‘RESET’ button must always be pushed in
(engaged) for correct operation.

The power supply cord must be replaced if it fails
to reset when the ‘TEST’ button is pushed in.

Important Safety Instructions