8

104787

PROPANE CONSTRUCTION HEATER

30,000 BTU/Hr CANADIAN

SERVICE
PROCEDURES

MOTOR

1.

Remove three screws that attach fan
guard to heater shell.

2.

Remove motor and fan guard from
heater shell (see Figure 9).

3.

Use hex wrench to loosen set screw which
holds fan to motor shaft (see Figure 10).
Remove fan. Be careful not to damage
the fan blade pitch.

4.

Remove two nuts and two screws that
attach fan guard to motor using nut-
driver. Remove fan guard from motor
(see Figure 11).

5.

Disconnect the green power cord wire
from motor and remove black and
white wire terminals.

6.

Discard old motor.

7.

Attach green power cord wire to motor.

8.

Attach fan guard to new motor with two
nuts and two screws.

9.

Replace black and white terminals.

10. Place fan onto motor shaft of new mo-

tor. Make sure set screw contacts flat
surface on motor shaft. Tighten set
screw firmly (40-50 inch-pounds).

11. Place motor and fan guard into rear of

heater shell. Make sure power cord is
properly located (see Figure 12).

12. Insert three screws through heater shell

and into fan guard. Tighten screws
firmly.

WARNING: Never service

heater while it is plugged in, con-
nected to propane supply, oper-
ating, or hot. Severe burns and
electrical shock can occur.

Figure 9 - Removing Motor and Fan Guard
from Heater

Figure 10 - Setscrew Location

Figure 11 - Removing or Attaching Fan
Guard from Motor

Figure 12 - Replacing Motor and Fan
Guard into Heater

Setscrew

ELECTRICAL SYSTEM

The entire electrical system for this heater is
contained within the motor. If any part of the
electrical system is damaged, you must re-
place motor.

Advertising