Storage, Maintenance, Specifications – Desa RCLP30 Manuel d'utilisation
Page 6

6
104787
PROPANE CONSTRUCTION HEATER
30,000 BTU/Hr CANADIAN
STORAGE
1.
Store propane tank(s) in safe manner.
See Chapter 5 of Standard for Storage
and Handling of Liquefied Petroleum
Gases, ANSI/NFPA 58 and/or CAN/
CGA B149.2. Follow all local codes.
Always store propane tanks outdoors.
2.
Place plastic cover caps over brass
fittings on inlet connector and hose/
regulator assembly.
3.
Store in dry, clean, and safe place. Do
not store hose/regulator assembly in-
side heater combustion chamber.
4.
When taking heater out of storage, al-
ways check inside of heater. Insects and
small animals may place foreign ob-
jects in heater. Remove motor and other
internal parts if needed to remove for-
eign objects (see Service Procedures,
page 8).
MAINTENANCE
CAUTION: Disconnect heater
from propane supply tank(s).
WARNINGS
• Never service heater while it is
plugged in, connected to pro-
pane supply, operating, or hot.
Severe burns and electrical
shock can occur.
• Keep heater clear and free from
combustible materials, gaso-
line, and other flammable va-
pors and liquids.
• Do not block the flow of com-
bustion or ventilation air.
1.
Keep heater clean. Clean heater annu-
ally or as needed to remove dust and
debris. If heater is dirty or dusty, clean
heater with a damp cloth. Use house-
hold cleaners on difficult spots.
SPECIFICATIONS
Output Rating kJ/Hr (BTU/Hr)
31,644 (30,000)
Fuel
Propane Vapor Only
Fuel Consumption
Liters (U.S. Gallons)/Hour
1.24 (.33)
Kg (Pounds)/Hour
.63 (1.4)
Supply Pressure To Regulator
Minimum (for purposes
138 kPa (20 psi)
of input adjustment)
Maximum
Tank Pressure or 1380 kPa (200 psi)
Regulator Outlet Pressure
69 kPa (10 psi)
Manifold Pressure
69 kPa (10.1 psi)
Hot Air Output
(CFM Approx)
4.95 m
3
(175)
Motor
3045 RPM
Electric Input
120 volt/60 hertz
Amperage
.6
Ignition
Manual, Piezo
Weight - Kg (Pounds)
Heater
4.08 (9)
Shipping
4.31 (9.5)
Size - L x W x H (Inches)
Heater
47 x 19.6 x 32.5 cm (18.5 x 7.7 x 12.8)
Temperature Range for Heater Operation
-6.7
°
to 29.5
°
C (-20
°
to 85
°
F*)
* When running heater in temperatures above 29.5
°
C (85
°
F), high internal temperatures
may cause thermal limit device to shut down heater.
2.
Inspect heater before each use. Check
connections for leaks. Apply mixture
of liquid soap and water to connections.
Bubbles forming show a leak. Correct
all leaks at once.
3.
Inspect hose/regulator assembly before
each use. If hose is highly worn or cut,
replace.
4.
Have heater inspected yearly by a quali-
fied service agency.
5.
Keep inside of heater free from com-
bustible and foreign objects. Remove
motor and other internal parts if needed
to clean inside of heater (see Service
Procedures, page 8).
6.
Clean fan blades each season or as
needed (see Fan, page 9).