SETUP PROCEDURES
This monitor offers various onscreen menus for setting user
preferences.
In the COMMUNICATION SETUP Menu, you can set the
parameters
for
communication
between
the
System
Controllers and the Monitors.
■ Displaying the Setup Menu
To display the Setup Menu, follow the procedure shown
below,
1. Confirm that the cameras and peripherals are connect
ed correctly and securely.
2. Turn the power of the monitor on by pressing the
POWER button.
3. Press the MENU button for 5 seconds or more.
At first the Display Setting menu described on page 10
appears, and then the COMMUNICATION SETUP
menu shown below.
Setup Menu
COMMUNICATION
SETUP
UNIT ADDRESS
CAM CONFIG
Ю
BAUD RATE
9600
DATA BIT
e
PARITY CHECK
NONE
STOP BIT
1
WAIT TIME
OFF
SETUP DISABLE
As shown above, the Setup Menu has seven main sub
menus.
One of these, CAM CONFIG, is further divided into addi
tional submenus.
1. After selecting the Setup Menu on the monitor screen,
move the cursor to SETUP DISABLE by pressing the
A
or ▼ button, then press the Q or 0 button.
Display of SETUP ENABLE in the Setup menu indicates
that setup is enabled.
—\
COMMUNICATION SETUP
UNIT ADDRESS
1
CAM CONFIG
BAUD RATE
9600
DATA BIT
8
PARITY CHECK
NONE
STOP BIT
1
WAIT TIME
OFF
SETUP ENABLE!
>
2. Move the cursor to the desired item by pressing the
A
or
T
button.
3. Select the desired item parameter by pressing the Q
or [+] button.
4. Press the MENU button to store the settings and return
to normal viewing
The following buttons are valid in this Setup menu.
A: Moves the cursor up.
T: Moves the cursor down.
E: Selects the mode or parameter.
0: Selects the mode or parameter,
4. To finalize the settings and return to normal viewing,
press the MENU button.
• Unit Address (UNIT ADDRESS)
This item lets you set the unit address of the monitor in the
system for RS-485 communication.
1, Move the cursor to the UNIT ADDRESS parameter by
pressing the the
A
or
T
button.
c
--------------------------------------
>
COMMUNICATION SETUP
UNIT ADDRESS
ill
CAM CONFIG
BAUD RATE
9600
DATA BIT
8
PARITY CHECK
NONE
STOP BIT
1
WAIT TIME
OFF
SETUP ENABLE
________________
_J
2. Select the unit address number to be used for RS-485
communication by pressing the Q or 0 button.
Select a parameter value between 1 and 99.
The factory default setting is 1.
8