Tweco 20 O2 Auto-Cut Manuel d'utilisation
Page 36

Manual No. 0-4816 Auto-Cut 200
2
3-12
INSTALLATION
3.07 Connect Work Cable and Pilot and Negative / Torch Leads
1. Pass the ends of the work cable and pilot and negative / torch leads upward through the leads bracket at
the bottom of the power supply rear panel, and through the openings in the connections cover support
panel.
2. Refer to the illustration. Connect the leads as shown. Tighten securely. Do not overtighten.
The clear connections cover must remain in place.
Negative Lead and Torch Lead are used interchangably during this operation
PILO
T
WORK
TORCH
Connection Panel
AC INPUT
Work
Torch
Lead Connection Detail
Connections Cover
Support Panel
Art # A-07661_AB
Connections Cover
Pilot
To Cutting Table
Leads Bracket
Work Lead
Pilot Lead -
To Remote Arc Starter
L1
L2
L
3
Torch Lead - To Remote Arc Starter