Installation – Regency Panorama P36E Medium Gas Fireplace Manuel d'utilisation
Page 20

P36E-4 Foyer à évent direct à dégagement zéro
20
Description
Simpson
Direct Vent Pro
®
Selkirk
Direct Temp™
American Metal
Products®
Amerivent Direct
Metal-Fab™
Sure Seal
Security
Secure- Vent®
ICC Excel
Direct
Attic Insulation Shield 12”
46DVA-IS
N/A@ FPI
N/A
4DAIS12
N/A
SV4RSA
N/A
Attic Insulation Shield -
Cold Climates
36”
N/A
N/A
4DAIS12
N/A
N/A
TM-4AS
High Wind Vertical Cap
46DVA-VCH
N/A
N/A
N/A
N/A
TM-4VT
High Wind Horizontal Cap
46DVA-HC
N/A
N/A
N/A
N/A
TM-4DHT
Horizontal Square Termination Cap
See
46DVA-HC
4DT-HHC
4DHC
4DHT
SV4CHC-1
TM-4HT
Vertical Termination Cap
N/A
4DT-HVC
4DVC
4DVT
SV4CGV-1
TM-4VT
Storm Collar
46DVA-08A
4DT-SC
4DSC
4DSC
SV4FC
TM-SC
Restrictor Disk
46DVA-RD
N/A
N/A
N/A
N/A
TM-4DS
Extended Vertical Termination Cap
46DVA-VCE
N/A
N/A
N/A
N/A
N/A
Chimney Conversion Kit A (USA only)
46DVA-KCA
N/A
N/A
N/A
N/A
TM-4CA6
Chimney Conversion Kit B (USA only)
46DVA-KCB
N/A
N/A
N/A
N/A
TM-4CA7
Chimney Conversion Kit C (USA only)
46DVA-KCC
N/A
N/A
N/A
N/A
TM-4CA8
Chimney Conversion Kit Masonry
(USA only)
46DVA-KMC
N/A
N/A
N/A
N/A
N/A
Wall Firestop
46DVA-WFS
N/A
N/A
N/A
N/A
TM-4TR
Colinear Flex Connectors
46DVA-ADF
N/A
N/A
N/A
N/A
N/A
Adjustable Flashing 0/12-6/12
N/A
4DT-ST14
4D12S
4DST14
SV4STC14
TF-4FA
Adjustable Flashing 6/12-12/12
N/A
4DT-ST36
4D36S
4DST36
SV4STC36
TF-4FB
Vinyl Siding Standoff
46DVA-VSS
4DT-VS
N/A
4DVS
SV4VS
TM-VSS
Vinyl Siding Shield Plate
N/A
4DT-VSP
N/A
N/A
SV4VS
N/A
Snorkel Termination 14”
46DVA-VCH
N/A
N/A
N/A
N/A
TM-4ST14
Snorkel Termination 36”
46DVA-HC
N/A
N/A
N/A
N/A
TM-4ST36
Basic Horizontal Termination Kit (A)
Disc.
4DT-HKA
4DHTK2
4DHTKA
SV-SHK
N/A
Horizontal Termination Kit (B)
46DVA-KHA
(Changed Components)
4DT-HKB
4DHTK1
4DHTKB
SV-HK
N/A
Vertical Termination Kit
Disc.
4DT-VKC
4DHTK
4DHTK
SV-FK
N/A
FPI
946-506/P
Vent Guard (Optional) for AstroCap
946-205
Vinyl Siding Shield for Riser Vent Terminal
510-994
Rigid Pipe Adaptor (Must use with all rigid piping)
946-208/P
Vent Guard (Optional) for Riser Vent Terminal
640-530/P
Riser Vent Terminal
946-523/P
AstroCap Horizontal Cap
946-605
Starter Collar Increaser 4” x 6-5/8” to 5” x 8”
946-206
Vinyl Siding Standoff for AstroCap
Note: When using Metal-Fab Sure Seal Rigid Piping - please note that the Adaptor (4DDA) must be used in conjunction with FPI Rigid Pipe Adaptor (510-994).
Note: Horizontal runs of vent must be level, or have a 1/4” rise for every 1 foot of run towards the termination.
Never allow the vent to run downward - this could cause high temperatures and may present a possible fi re hazard.
Offset Pipe Selection: Use this table to determine offset pipe lengths.
Pipe Length
(L)
4” x 6-5/8” Venting
For specifi c instructions on venting components - visit the
manufacturers website listed below.
Run (X)
Rise (Y)
0” (0mm)
4-7/8” (124mm)
13-7/8” (340mm)
Simpson Direct Vent Pro: www.duravent.com
6” (152mm)
8” (203mm)
16-1/2” (419mm)
Selkirk Direct-Temp: www.selkirkcorp.com
9” (229mm)
10-1/8” (257mm)
18-5/8” (473mm)
American Metal Products: www.americanmetalproducts.com
12” (305mm)
12-1/4” (311mm)
20-3/4” (527mm)
Metal-Fab Sure Seal: www.mtlfab.com
24” (610mm)
20-5/8” (524mm)
29-1/8” (740mm)
Security Secure Vent: www.securitychimneys.com
36” (914mm)
29” (737mm)
37-1/2” (953mm)
Industrial Chimney Company: www.icc-rsf.com
48” (1219mm)
37-7/16” (951mm)
45-15/16” (1167mm)
INSTALLATION
Mettre les conduits d’évacuation horizontaux au niveau ou les installer de façon à ce que leur élévation ne dépasse pas ¼ pouce par pied de conduits jusqu’à la sortie.
S’assurer qu’aucune section du système d’évacuation n’est dirigée vers le bas. Une inclinaison descendante peut provoquer des hausses de température et comporter
un risque d'incendie.