Drain pump removal instructions – MARVEL Scientific MPRO30iMT Manuel d'utilisation
Page 24

DRAIN PUMP REMOVAL INSTRUCTIONS
24
Figure 26
Unscrew the leveling leg so the
end of the threads is flush with
the top of the nut insert.
Remove these 4 hose clamps, then re-
move the 3 tubes from the drain pump
It may be necessary to disconnect this
electrical connection on factory installed
drain pumps
Drain pump
ground wire
connection
Drain Pump Removal Instructions:
1. Unplug ice machine from the electrical supply and remove
the rear access cover from the ice machine. (See page 5 for
instructions).
2. Unscrew the leveling leg in the back corner until the end of
the threaded portion is flush with the threaded nut insert in
the base. (see Figure 26 ).
3. Unscrew the 4 hose clamps and remove the 3 hoses from
the front of the drain pump. (See Figure 26).
4. Rotate the drain pump and remove from the ice machine,
(See Figure 25). It may be necessary to disconnect the
ground wire connection in the back flange of the cabinet.
(See Figure 26).
5. Disconnect the ice machine power cord from the drain
pump (See Figure 27).
6. To drain water from the pump follow step 14 and 15 on
page 23.
7. Installation of drain pump is reverse of this procedure.
Figure 25
Rotate drain pump
and remove from
back of ice machine.
Drain valve