Det-Tronics X3301 Multispectrum IR Flame Detector with Pulse Output Manuel d'utilisation
Page 10
![background image](/manuals/557674/10/background.png)
95-6528
11.1
8
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
+
–
(A) +290 Vcc
B - INPUT 1
B - INPUT 2
B - INPUT 3
B - INPUT 4
B - INPUT 5
B - INPUT 6
B - INPUT 7
B - INPUT 8
D1-1
oi DRIVER
D1-2
oi DRIVER
D1-3
oi DRIVER
D1-4
oi DRIVER
D1-5
oi DRIVER
D1-6
oi DRIVER
D1-7
oi DRIVER
D1-8
oi DRIVER
D2-1
oi DRIVER
D2-2
oi DRIVER
D2-3
oi DRIVER
D2-4
oi DRIVER
D2-5
oi DRIVER
D2-6
oi DRIVER
D2-7
oi DRIVER
D2-8
oi DRIVER
DMA OUT AVAILABLE
DMA OUT
DMA IN
DATA STROBE
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
ZONE OUTPUT 1
ZONE OUTPUT 2
ZONE OUTPUT 3
ZONE OUTPUT 4
ZONE OUTPUT 5
ZONE OUTPUT 6
ZONE OUTPUT 7
ZONE OUTPUT 8
FIRE LOGIC “A”
FIRE LOGIC “B”
ALARM OUTPUT
EXTERNAL RESET/INHIBIT
OUTPUTS INHIBITED
FAULT OUTPUT
EXTERNAL ACCEPT
STATUS & DET. OUTPUT S1
STATUS & DET. OUTPUT S2
STATUS & DET. OUTPUT S3
STATUS & DET. OUTPUT S4
STATUS & DET. OUTPUT S5
STATUS & DET. OUTPUT S6
STATUS & DET. OUTPUT S7
STATUS & DET. OUTPUT S8
DATA BUS 0
DATA BUS 1
DATA BUS 2
DATA BUS 3
DATA BUS 4
DATA BUS 5
DATA BUS 6
DATA BUS 7
CHASSIS (EARTH) GND
DMA IN AVAILABLE
J1-7
J1-15
J1-5
J1-13
J1-6
J1-14
J1-8
J1-16
J1-9
J1-17
J1-10
J1-18
J1-11
J1-19
J2
CONTRÔLEUR R7404
J1
10 TO 38 Vcc
}
#2
#1
#19
#22
X3301
DÉTECTEUR 1
#2
#1
#19
#22
#2
#1
#19
#22
X3301
DÉTECTEUR 2
#2
#1
#19
#22
#2
#1
#19
#22
X3301
DÉTECTEUR 3
#2
#1
#19
#22
#2
#1
#19
#22
X3301
DÉTECTEUR 4
#2
#1
#19
#22
#2
#1
#19
#22
X3301
DÉTECTEUR 5
#2
#1
#19
#22
#2
#1
#19
#22
X3301
DÉTECTEUR 6
#2
#1
#19
#22
#2
#1
#19
#22
X3301
DÉTECTEUR 7
#2
#1
#19
#22
#2
#1
#19
#22
X3301
DÉTECTEUR 8
#2
#1
#19
#22
B2071
NOTE: SI LE PÔLE "-" DE L'ALIMENTATION NE PEUT PAS ÊTRE
CONNECTÉ A LA MASSE DU CHÂSSIS (TERRE), CONNECTER
UNE CAPACITÉ NON POLARISÉE DE 0,47µF 400 Vcc ENTRE J1-2 ET J2-64.
NOTE: 2,5 A SOUS 24 Vcc REQUIS POUR HUIT DÉTECTEURS.
NOTE: LES CIRCUITS DÉTECTEUR/CONTRÔLEUR SONT CONFORMES
AUX EXIGENCES DE CÂBLAGE CLASS B, STYLE 0.5
(LIGNES DE NOTIFICATION A ET C).
24
Vcc
+
–
62
63
64
VERS J1-2
0,47 µF / 400 Vcc
11.64 pt
NON POLARISÉE
SYSTÈMES PROTÉGÉS CONTRE
LES DÉFAUTS DE MASSE
N° BORNE
FONCTION
1/11
TENSION cc - (FIL "C")
2/12
TENSION cc + (FIL "A")
19
SIGNAL (FIL "B")
22
oi
(FIL "D")
IDENTIFICATION DES BORNES POUR LE X3301
AVEC SORTIE IMPULSIONS
NOTE: NE PAS CONNECTER LE FIL "A" (#2/12) DU X3301
SUR LA BORNE J1-3 DU R7404 (290 Vcc)
11.64 pt
Figure 6—Système Type, Détecteurs X3301 Câblés sur un Contrôleur R7404