53) troubleshooting, Caution, Warning – Aquascape AquaSurge (98125, 99546, 99547 & 99548) Manuel d'utilisation
Page 5: 2) installation

5
3) Troubleshooting
3.1 Reduced Flow
• Pump or plumbing may be clogged. It may be necessary to clean the filter ring and impeller.
3.2 Pump Hums and Doesn’t Push Water
• Make sure nothing is blocking or wrapped around the impeller.
• Make sure the pump is receiving the correct voltage.
3.3 Pump Not Working
• The breaker may be tripped.
• The pump is not receiving the correct voltage.
CAUTION
• Submersible pump.
• For outdoor and indoor use.
• Thermally protected.
• Enclosure type 3.
• This pump has been evaluated for use with water only.
• This pump is to be used in a circuit protected by a ground fault circuit interrupter.
• Do not run dry.
WArNING
• To reduce the risk of electric shock, connect only to a properly grounded, grounding
type receptacle.
• Risk of electric shock – This pump has not been investigated for use in swimming pool
or marine areas.
• To reduce the risk of electric shock, install only on a ground-fault
circuit-interrupter (GFCI).
AquaSurge
™
High Efficiency Pump Performance
Flow Rates (in GPH)
Model
Discharge
Watts
Max Head
Height
0’
5’
10’
15’
20’
2000 gph
1”
250
21’
1900
1500
1300
900
450
3000 gph
1.5”
180
15’
3328
2853
1902
4000 gph
1.5”
220
16.4’
3960
3300
2700
1426
5000 gph
1.5”
250
19.6’
4752
4280
3328
2377
7000 gph
2”
700
22’
6600
5100
4000
2800
1000
2) Installation
2.1 Assembly of the Filter Ring
The filter ring is designed to attach to the pump when it is being mounted in the verti-
cal position. If not mounting the pump vertically, the filter ring can either be attached or
discarded. When attaching the filter ring to the pump, make sure the tabs on the filter ring
line up with the tabs on the outer filter. If the tabs are not lined up, the filter ring can block
the openings on the outer filter causing the pump to suck dry.
2.2 Basic Installation
• The AquaSurge
™
pump is designed to be placed inside a skimmer, snorkel, sump or
basin. Depending on the situation, the pump can be placed horizontally or vertically. If
being placed vertically, simply flip the filter ring around and snap the pump on the ring.
The ring snaps snugly in place for stability.
• The AquaSurge
™
pump comes with a threaded coupler and a 90° elbow. Depending on the
application, either one of these fittings will be used.
• Thread the plumbing assembly on the discharge of the pump.
• Connect pump to an outlet that is protected by a ground fault interrupter (GFCI).
Unnecessary overtightening will cause damage to both pipe and fittings. When threading
plastic to plastic or plastic to steel, precaution should be taken to prevent excessive
tightening, causing damage to the plastic pipe or fittings. The correct degree of tightness
may be determined by threading the connection hand tight, plus a quarter to half turn.
Once you have properly tightened the reducer bushing or coupler to the pump, care must be
taken to not over tighten these fittings during the installation of the elbow. Place a wrench
on the coupling and hold it secure, preventing it from over tightening during the tightening
of the elbow. Failure to do this may cause damage to the fittings and the pump housing.
Vertical placement
99545 AquaSurge Instructions FINAL 05-09.indd 5
5/8/09 8:59:50 AM