Regular maintenance – NaceCare Solutions TTB1120 Manuel d'utilisation

Page 14

Advertising
background image

14

AlWAyS ENSURE THAT THE bATTERy IS DISCONNECTED

PRIOR TO ANy MAINTENANCE OPERATION

!

!

After use, empty waste-water tank using
emptying hose

and flush-out with clean

water (Fig.29).

A

Remove the two hoses to disconnect the separator from the
machine (Fig.30).
Lift off the separator. The separator has a sealing-rubber
which should be examined at every clean-down (Fig.31).
Rinse using clean water.

The TTB / ETB Range has been designed with ease of use in mind, this included easy stripping-down and cleaning.

Remove the filter fitted into the separator and flush with clean water (Fig.32)(Fig.33).
Placed into the top tank is grey filter basket, clean and flush with clean water (Fig.34) (Fig.35).

A

Regular Maintenance

The Bottom (Clean Water) tank is attached to the chassis and should only
be removed by a competent service engineer (Fig.36).

Clean by flushing with clean water if required.

Excess water can be drained using the clear dump hose fitted to the rear
of the machine.

Located under the left hand side is a clean water filter, ensure the clean
water tap is turned off before removing this filter (Fig.37).

Clean and flush with clean water if required.

Fig.29

Fig.30

Fig.31

Fig.32 Fig.33

Fig.36

Fig.37

Fig.34

Fig.35

Fig.37