Use the periscope kit to locate the air termination above grade. The periscope must be installed so that when
fi nal grading is completed, the bottom air slot is located a minimum 12” above grade. The maximum allowable
vent length is 10’ for a fi replace and 8’ for a stove.

9.4A

3.3 SPECIAL VENT INSTALLATIONS
3.3.1 PERISCOPE TERMINATION

12"

MINIMUM

TO GRADE

12"

MINIMUM

TO GRADE

24" MINIMUM

24" MINIMUM

35 1/2"

20” MAXIMUM

6” RISE
MINIMUM

3.3.2 CORNER TERMINATION

The maximum vent length for a corner installation is 20" of horizontal run, in addition to the 45° offset. In this
case zero rise is acceptable. See illustrations below. It is recommended to maintain a 6" rise.