Warning, 0 pre-installation preparation – Napoleon Fireplaces 1600C-1 Manuel d'utilisation
Page 8

W415-0721 / B / 05.03.11
8
3.0 PRE-INSTALLATION PREPARATION
Have an authorized dealer install the appliance. If you install the appliance yourself, have your dealer review
your installation plans and/or installation.
Draw out a detailed plan of the installation including dimensions and verify the dimensions with the require-
ments listed in this manual.
You may wish to adjust the appliance position slightly to ensure the vent does not intersect with a framing
member. Appliance must be positioned so that no combustibles are within, or can swing within (e.g. drapes,
doors), 48” of the front of the appliance.
67.1A
3.1 APPLIANCE
PLACEMENT
!
WARNING
DO NOT INSTALL INTO ANY AREA HAVING LESS THAN 7 FEET (CEILING OF ENCLOSURE TO APPLI-
ANCE BOTTOM, EXCLUDING HEARTH HEIGHT).
3.2
CLEARANCE TO COMBUSTIBLES
MINIMUM CLEARANCES TO APPLIANCE
WITHOUT REAR SHIELD
WITH REAR SHIELD
TYPE
SINGLE
DOUBLE
SINGLE DOUBLE
A
16"
16"
16"
16"
B
24"
18"
16"
12"
C
15"
11"
15"
11"
D
25"
18"
25"
18"
IMPORTANT: When using a double wall
connector it must be listed for a minimum
clearance of 12" or less.
B
A
C
C
D
D
D
3.2.1 STOVE INSTALLATION USING SINGLE OR DOUBLE WALL CONNECTORS
WITH OR WITHOUT REAR SHIELD.
Model 1600C-1 may be installed into an alcove
having a depth of not more than 4 feet and a
height of at least 7 feet, when using a listed
double wall connector that is rated for a mini-
mum 12” clearance to combustible material.
Walls shall not extend from the front of the
appliance when installed in the alcove confi gu-
ration.
* May be reduced to 16" if EPRS is used.
16”
22”
*
16”
4 FT
84”
ILLUSTRATED WITH .75” HEARTH PAD
3.3 ALCOVE
INSTALLATION