Napoleon Fireplaces High Country 6000 - NZ6000 Manuel d'utilisation
Page 22

W415-0594 / E / 10.19.12
22
5.1 WHEN USING A SOLID PACK CHIMNEY
combustible
facing and wood
framing may start
at 96" above the
base of the unit
Face and enclosure
ceiling metal studs, both
clad with cement board
Face must have a
minimum 8' height
of cement board
depending upon
ceiling height
Cement board and steel studs
on enclosure ceiling
not required above 10'
Enclosure ceiling
height from
7' to 10'
6"
Cement board from
the side of the unit
to combustibles
Cement board
Metal Studs
The appliance face and
enclosure ceiling must
be framed using 2x4
metal studs.
The minimum
enclosure ceiling height
is 7 feet.
Non - combustible
materials (cement
board and metal studs)
must be used.
5.2 WHEN USING AN AIR COOLED CHIMNEY
Facing on metal
studs, clad with
cement board
Face must have a
minimum 7' height
of cement board
Minimum
enclosure ceiling
height 7'
6"
Cement board from
the side of the unit
to combustibles
combustible
facing and wood
framing may start
at 84" above the
base of the unit
Cement board
Metal Studs
ENCLOSURE CEILING
METAL STUDS
FLOOR JOISTS
CEMENT BOARD
MINIMUM 7' TO BASE OF THE FIREPLACE