7 air cooled chimney installation – Napoleon Fireplaces High Country 6000 - NZ6000 Manuel d'utilisation
Page 20

W415-0594 / E / 10.19.12
20
4.7 AIR COOLED CHIMNEY INSTALLATION
A.
Remove the knock out.
B.
Cut away the insulation to gain access to the ring.
C.
Remove the ring secured by four screws.
D.
Slide the starter collar through the insulation wrap and
affi x using the four screws removed in step 3.
E.
Secure the inner liner of the chimney to the appliance
8" collar using 3 screws supplied with the starter collar
(W170-0098).
F.
Follow the chimney manufacturer's instructions for
installing the chimney.
KNOCK-OUT
1
INSULATION
2
STARTER COLLAR
4
RING
3
AVERTISSEMENT
:
AIR COMBURANT
SEULEMENT
W
ARNING:
COMBUSTION AIR
ONL
Y
W
ARNING:
BLOWER
CONNECTION ONL
Y
AVERTISSEMENT
:
CONNEXION DE LA
SOUFFLERIE
SEULEMENT
Use only the following brand and type of chimney.
CHIMNEY COMPO-
NENTS
FMI 8DM
12" Chimney Section
12-8DM
18" Chimney Section
18-8DM
24" Chimney Section
24-8DM
36" Chimney Section
36-8DM
48" Chimney Section
48-8DM
Offsets
30E-8DM
Flashing
6F8 or 12F8
Chimney Cap
RTL-8HT
Roof Support
38 RS
Firestop
FS-8DM
CHIMNEY COMPO-
NENTS
WOLF STEEL
Starter Collar
NZAC-KT