Napoleon Fireplaces STARfire 52 - HDX52 Manuel d'utilisation
Page 28

28
W415-1276 / A / 05.09.14
EN
* Within the appliance enclosure a 11 1/2" (292mm) clearance between the top of the vent pipe and
combustible materials is required. All other clearances within the enclosure, including where the vent pipe exits
the enclosure are subject to 2" (51mm) to the sides and bottom and 5" (127mm) to the top for horizontal and
1" (25mm) for vertical.
** See venting section.
IMPORTANT: THE FIRESTOP ASSEMBLY PROVIDED MUST BE USED WHEN THE VENT PIPES PASS
THROUGH ANY WALL OR ARE TERMINATED HORIZONTALLY.
71 1/2"
1816mm
2"
51mm
41 7/8"
1064mm
55 1/4"
1403mm
88"
2235mm
2"
51mm
5"
127mm
FIRESTOP
ASSEMBLY
11 1/2"
292mm
STEEL STUD
FRAMING
NON-COMBUSTIBLE
MATERIAL
0” IF NON-COMBUSTIBLE
FINISHING MATERIAL
IS USED SUCH AS
BRICK AND STONE.
65 7/8"
1673mm
ENCLOSURE
HEIGHT