Installation, Drain instruction – Doyon JA5P2618-2 Manuel d'utilisation
Page 8

A-5
INSTALLATION
IN GENERAL
Take off the packaging material with care. Take off all the material used for packing and accessories.
If the equipment is delivered with casters, always lock them after installation and use flexible wire. It
must also be installed with restraining device (chain comes with the oven) to guard against transmission
of strain to the gas supply and connectors.
1. To the electrician
Electrical supply installation must be in accordance with the electrical rating on the nameplate.
WARNING
The electrician must make sure that the supply cable does not come in contact with
the oven top which becomes hot.
2. To the plumber
This equipment is to be installed to comply with the applicable federal, state or local plumbing codes.
Connect the steam system (1/4 NPT) to the cold water distribution network.
We highly recommend to use a water softener to eliminate minerals in the water.
We suggest you to use CUNO # CFS6135 (Doyon part number PLF240).
WARNING
Do not adjust the needle valves, it has been done at the factory.
DRAIN INSTRUCTION
At the rear center of the oven there is a gravity drain connection . When the oven leaves the factory this
drain is closed with 2 caps one in the inside of the oven and one at the outside of the oven in case that
this drain is not needed .
If you need to use this drain remove the caps from the inside and install the filter that is situated at the
left side of the back panel.
IMPORTANT: For the outside drain it is very important that the drain is directed towards the floor and
should reach the floor drain.
The drain must also vented and be conformed to the local code.