If steam device of the oven does not work
properly.
The oven must be at 300°F before you use the
steam system. If not, no steam will appear in the
oven.
Check if the water supply valve (of the building)
is open.
Check if the water needle valve (of the oven) is
open one eighth of a turn. Close it and open it
one eighth of a turn maximum.
Check the solenoid valve.
Be sure to inject steam while the fan is running.
The steam button light should lite during the
steam injection.
ACCESSORY 1 FAILURE OVERHEAT
WARNING light is on, and you hear the
warning buzzer.
Check if the cooling fan airflow is not obstructed.
Check if the cooling fan is running. If the
malfunction light goes on, or if the audible
sound, appliance is malfunctioning.
Turn off or disconnect appliance from power
supply and have serviced by a electrician.
Unit goes into Off mode with error message
CAVITY PROBE ERROR
Cavity probe alarm occurs when units detects a
defective cavity temperature probe.
Check cavity probe connection.
Replace cavity probe.