26

504523

• Main collector duct should be sized according to

specifications shown below.

NOTE: Main collector duct should be equipped with
an auxiliary fan that can maintain the duct airflow at
a minimum of 366 m (1200 feet) per minute. If you do
not have a fan, clean the main collector duct at least
twice a year.

D039IE3D

WEATHER HOOD

OR SWEEP ELBOW

(No cap or screen)

WALL

PARAPET

ROOF

180˚ SWEEP

ELBOW
(No cap

or screen)

60.96 cm

(24") MIN.

VERTICAL DUCT

HORIZONTAL DUCT

MAIN COLLECTOR DUCT

MAIN COLLECTOR DUCT

Number of Dryers

Minimum Diameter of
Horizontal Collector Duct

Minimum Diameter of
Vertical Collector Duct

2

17.8 cm (7 inches)

20.3 cm (8 inches)

3

20.3 cm (8 inches)

22.9 cm (9 inches)

4

22.9 cm (9 inches)

25.4 cm (10 inches)

5

25.4 cm (10 inches)

27.9 cm (11 inches)

6

27.9 cm (11 inches)

30.5 cm (12 inches)

7

30.5 cm (12 inches)

32.6 cm (13 inches)

8

30.5 cm (12 inches)

35.6 cm (14 inches)

9

32.6 cm (13 inches)

38.1 cm (15 inches)

10

35.6 cm (14 inches)

38.1 cm (15 inches)

11

35.6 cm (14 inches)

40.6 cm (16 inches)