Location Requirements . . .

Select a location with a solid floor.

No other fuel burning appliance should be installed in the
same closet with the dryer.

The dryer must not be installed or stored in an area where
it will be exposed to water and/or weather.

Leveling legs can be adjusted from inside the dryer with
a 1/4" driver. All four legs must rest firmly on the floor so

the weight of the dryer is evenly distributed. The dryer
must not rock.

The dryer needs sufficient clearance and an adequate air
supply for proper operation and ventilation, and for easier
installation and servicing. (Minimum clearances are
shown below.)

CLOSET

DOOR

D337IE3A

FRONT VIEW

(w/o Closet Door)

SIDE VIEW

A

A

C

A

D

E

B

CENTERED

AIR

OPENINGS (G)

(2 Openings

Minimum)

FRONT VIEW

(Closet Door)

F

F

OUTER

WALL OF

ENCLOSURE

**42"

** NOTE: For new installations, locate top of wall vent 106 cm (42 inches) above floor to make venting

easier to connect.

AREA

DESCRIPTION

FREE STANDING /
ALCOVE INSTALLATION
(See Illustration)

CLOSET INSTALLATION
(See Illustration)

A

Dryer sides and rear clearance

0 cm (0")

0 cm (0")

B

Dryer top clearance

30.5 cm (12")

30.5 cm (12")

C

Dryer front clearance

Not Applicable

5.1 cm (2")

D

Exhaust duct clearance to
combustible material

5.1 cm (2")

5.1 cm (2")

E

Weather hood to ground
clearance

30.5 cm (12")

30.5 cm (12")

F

Distance from floor or ceiling
to hole edge

Not Applicable

7.6 cm (3")

G*

Area of centered air openings
in closet door

Not Applicable

260 sq. cm/open (40 sq. in.)

*Louvered door with equivalent air openings is acceptable. (Minimum clearances are shown.)