Dryer slide extension, Warning – Alliance Laundry Systems 504523R3 Manuel d'utilisation

Page 11

Advertising
background image

504523

9

Dryer Slide Extension . . .

1. Assemble coin slide extension, No. 503733, to top

side of coin slide using two Phillips head screws and
lockwashers, No. 03950. Tighten firmly.

2. Install slide extension modifier, No. 501796, as

follows:

NOTE: Dryers equipped with Greenwald coin slides
(except for Greenwald Comet Slide or Greenwald
Tokette Slide) do not require the use of the slide
extension modifier.

ESD Coin Slide – Mount slide extension
modifier, No. 501796, to the underside of slide
extension, No. 503733. Align the hole in the slide
extension modifier with hole “A” in the slide
extension and install self-tapping screw, No.
501086. Tighten firmly.

GREENWALD Comet Slide, GREENWALD
Tokette Slide or MONARCH Coin Slide

Mount slide extension modifier, No. 501796, to
the underside of slide extension, No. 503733.
Align the hole in the slide extension modifier with
hole “B” in the slide extension and install self-
tapping screw, No. 501086. Tighten firmly.

3. Reinstall coin slide in dryer meter case.

4. CHECK DRYER OPERATION – Connect electrical

power to dryer. Place required number of coins in
coin slide. Push slide in, and observe through service
door opening in meter case. The slide extension
should be contacting the accumulator actuator arm
and moving back with slide travel.

When slide is pushed all the way in, slide is retracted.
Accumulator actuator arm should remain back until
slide extension is moved forward and contacts
actuator arm agian, returning arm to starting position.

5. After completing the dryer check, reinstall service

door on top of meter case.

NOTE: When reinstalling service door, front of door
must be inserted at about a 45

° angle in order to engage

notched tabs with internal rib at top of meter case.

To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be

reconnected to ensure that the dryer is properly grounded.

W001R1

WARNING

D019KE1C

COIN

SLIDE

03950

PHILLIPS

HEAD

SCREWS

AND

LOCKWASHERS

HOLE "B"

503733

SLIDE

EXTENSION

HOLE "A"

501796

SLIDE EXTENSION

MODIFIER

501086

SELF-TAPPING

SCREW

D044KE1A

ACCUMULATOR

ACTUATOR ARM

SLIDE

EXTENSION

MODIFIER

SLIDE

EXTENSION

COIN

SLIDE

Advertising