Diagrammes, L9008 – Lincoln Electric IM420 IDEALARC DC-1000 Manuel d'utilisation
Page 28

F-5
DIAGRAMMES
F-5
D
IAG
R
A
MM
E
DE
C
Â
B
L
AGE
–
DC
-1000
L
9008
VERS LA
MASSE CONFORMÉMENT
AU CODE ÉLECTRIQUE NA
TIONAL
VERS
L
’ALIMENT
A
TION
TRIPHASÉE
VERS
LES BOBINES
PRIMAIRES
PANNEAU D’ENTRÉE TENSION SIMPLE OU DOUBLE
ILLUSTRÉ BRANCHÉ POUR
TENSION F
AIBLE
VERS LA
MASSE CONFORMÉMENT
AU CODE ÉLECTRIQUE NA
TIONAL
VERS
L
’ALIMENT
A
TION
TRIPHASÉE
VERS LES BOBINES PRIMAIRES
PANNEAU D’ENTRÉE TENSION DE 380 VOL
TS OU TRIPLE
ILLUSTRÉ BRANCHÉ POUR 380 VOL
TS
VERS LA
MASSE CONFORMÉMENT
AU CODE ÉLECTRIQUE NA
TIONAL
VERS
L
’ALIMENT
A
TION
TRIPHASÉE
VERS
LES BOBINES
PRIMAIRES
PANNEAU D’ENTRÉE 380/500 VOL
TS OU 460/575 VOL
TS
ILLUSTRÉ BRANCHÉ POUR
TENSION F
AIBLE
NOTES
:
N.A. LES CONEXIONS 13, 14 ET
15 SONT
PRÉSENTES UNIQUEMENT
SUR LES MACHINES
À 380/500 ET
460/575 VOL
TS.
N.B. LES CONNEXIONS 10, 1
1 ET
12 NE SONT
P
AS PRÉSENTES SUR LES MACHINES À 380 VOL
TS
OU
TENSION
TRIPLE.
N.C. LES CONNEXIONS VERS H2, H3 OU H4 DÉPENDENT
DE LA
TENSION D’ENTRÉE. VOIR LES
INSTRUCTIONS DE RACCORDEMENT
DE L
’ALIMENT
A
TION D’ENTRÉE. INSTRUCTIONS POUR H4:
LA
CONNEXION H4
APP
ARAÎT
UNIQUEMENT
SUR LES MACHINES À 380V ET
À
TENSION
TRIPLE.
N.D. 2CR EST
ILLUSTRÉ EN
T
ANT
QUE RELAIS UNIPOLAIRE UNIDIRECTIONNEL.SI 2CR EST
UN 3PDT
,
LE FIL
271 SE BRANCHE SUR LA
TERMINALE 4
AU LIEU DE LA
TERMINALE 5.
N.E. N’EST
P
AS COMPRIS SUR
T
OUS LES MODÈLES.
CONTRÔLE DE SOR
TIE
TERMINALE CENTRALE SUR
SUPPOR
T
DE FUSIBLE
KIT
MESUREUR
(EN OPTION)
LAMPE
TÉMOIN
MOTEUR DU
VENTILA
TEUR
THERMOST
A
T
SECONDAIRE
THERMOST
A
T
DE
L
’ÉTRANGLEUR
TCI DE
CONTRÔLE
TCI AMOR
TISSEUR
À FRICTION
DE SOR
TIE
SOR
TIE
500 AMP
SOR
TIE
1000 AMP
FILS DISPONIBLES
VERS
TCI DU CIRCUIT
D’ALLUMAGE
AMOR
TISSEURS À
FRICTION SCR
DÉRIV
A
TION DE SOR
TIE
TCI DU
CIRCUIT
D’ALLUMAGE
FILS DISPONIBLES
VERS
TCI DU CIRCUIT
D’ALLUMAGE
VERS BOBINAGE AUXILIAIRE
T1
SÉQUENCE DE NUMÉRA
TION DE LA
CA
VITÉ DU CONNECTEUR
(VUE DU CÔTÉ COMPOSANTS DU
T
ABLEAU)
SW1 PUISSANCE D’ENTRÉE
SW2 POLARITÉ DE L
’ÉLECTRODE
SW3 CONTRÔLE DE SOR
TIE
SW4 MODE DE SOUDAGE
F1 FUSIBLE À RET
ARDEMENT
DE 8
AMP
R1 POTENTIOMÈTRE 10K OHM
R2 30 OHM, 300 W
R3 10 OHM, 50 W (20 W SUR MODÈLES PLUS
ANCIENS)
T1
TRANSFORMA
TEUR DE PUISSANCE PRINCIP
AL
T2
TRANSFORMA
TEUR DE CONTRÔLE
L1 ÉTRANGLEUR DE SOUDAGE À COURANT
F
AIBLE
1CR CONT
ACTEUR D’ENTRÉE
2CR RELAIS DE PROTECTION CONTRE LES
A
V
ARIES
3CR CONT
ACT
EN
AMPOULE
ACTIVÉ P
AR LE COURANT
4CR RELAIS PILOTE DE SOR
TIE
LÉGENDE :
SYMBOLES ÉLECTRIQUES D’APRÈS E1537.
COUVERCLE
DU BOÎTIER
DE CONTRÔLE
BOÎTIER DE
CONTRÔLE
POIGNÉE DE
LEV
AGE
BOÎTIER
D’ENTRÉE
9919
-
9925
,
10293
,
1
1305
,
1
1330
,
11
3
3
1
,
1
1332
,
1
1333
,
1
1334
POUR DES CODES
NOTE : Ce diagramme a valeur de référence uniquement. Il peut ne pas être exact pour toutes les machines couvertes par ce manue
l. Le diagramme spécifique pour un code particulier est collé à l
ʼintérieur de la machine sur l
ʼun des pan-
neaux de la console. Si le diagramme est illisible, écrire au Département de Service afin d
ʼen obtenir un autre en remplacement. Donner le numéro de code de l
ʼappareil.