Installation, Figure 1, Avertissement – Lincoln Electric IM830 EAGLE 10,000 Manuel d'utilisation

Page 16

Advertising
background image

Service de 3

c

â

bles de 240

Volts et 40 Hz.

COMPTEUR DE

PUISSANCE DE

LA COMPAGNIE

240 VOLT

120 VOLT

120 VOLT

CHARGE

N

BARRE

CONDUCTRICE

TERRE

PROTECTION CONTRE

DISJONCTEUR BATIMENT

ET SURCHARGE DU

COURANT

DE SERVICE

GND

N

NOTE: CABLE CONDUCTEUR DE CUIVRE No.6

VOIR

LE CODE

É

LECTRIQUE NATIONAL POUR DES ALTERNATIVES

DE RECOMMANDATIONS DE TAILLE DE CABLES.

240 VOLT

CONDUCTEUR RACCORD

Й А

TERRE

40 AMP

240 VOLT

DISJONTEUR A

DOUBLE POLE

LE R

É

GIME NOMINAL DE L

INTERRUPTEUR

À

DOUBLE POLE ET DOUBLE JET DOIT ETRE

É

GAL OU SUP

É

RIEUR A LA PROTECTION

DE SURCHARGE DU COURANT DE SERVICE

DU BATIMENT.

FICHE NEMA TYPE

14-50 DE

50 AMP.

ET

120/240 VOLTS

R

É

CEPTACLE DE 50 AMP.

ET 120/240 VOLTS

NEUTRE

A-9

INSTALLATION

EAGLE 10,000

A-9

Le branchement de la

«

EAGLE 10,000

»

au c

â

blage

du b

â

timent doit

ê

tre effectu

é

par un

é

lectricien avec

permis et doit respecter le Code

É

lectrique National et

autres codes

é

lectriques en vigueur.

Figure 1

BRANCHEMENT DE LA

«

EAGLE 10,000

»

AU CABLAGE DU BATIMENT

AVERTISSEMENT

Advertising