Connecting to an external fuel tank (blaze 600 d), Electrical – CAMPO EQUIPMENT BLAZE 600 D Manuel d'utilisation
Page 6

CAMPO EQUIPMENT CO. LTD. (ECOBLAZE)
6 Carson Court, Brampton, ON, CANADA, L6T 4P8
Tel: (905) 793-2525 | Fax: (905) 793-8768 | www.campoequipment.com
CONNECTING TO
AN
EXTERNAL FUEL
TANK
(BLAZE 600 D)
Beckett CF800 is fitted
with 3/8” SAE male
fittings and is set up for a
2 line system to eliminate
priming. Ensure fuel tank
has an supply line and a
return line and connect
the supply line to the 3/8”
SAE fitting on the inlet
side of the fuel filter and
the return line to the
return fitting located on
the Beckett Burner pump.
For a 1 line system
remove bypass plug located on inlet port of Beckett Pump and just connect fuel line to inlet side of
fuel filter.
ELECTRICAL
WARNING: ELECTRICAL GROUNDING INSTRUCTIONS
THIS APPLIANCE IS ABLE IS TO RECEIVE 1 PHASE
120V SUPPLY MUST BE AVAILABLE.
INSTALLATION
10/3 upto 100ft
NOTE: IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE
REPLACED, IT MUST BE REPLACED WITH TYPE TEW 14GA WIRE OR ITS EQUIVALENT.
ELECTRICAL SYSTEM
BLAZE
600 D
Volts-Hertz-Phase
120-60-1
Full Load (Amps) (1PH)
17
Max fuse size (Amps) (1PH)
with time delay
20
The electrical grounding of the heater shall be in compliance with the National Electrical Code, ANSI/NFPA
70, or the CSA C22.1, Canadian Electrical Code, Part I
Head Setting
1
Air Setting (Beckett-
Shutter/Band))
3/0
APPROVAL AGENCY
OMNI
DRY WEIGHT (lbs)
700
Dimensions
70" X 26" X 61"
FLUE SIZE
6”