INSTALLATION CLEARANCES
MAXIMUM ALLOWABLE DUCT LENGTHS BLAZE 600 D - 150ft
INLET DUCTS 16” on each inlet
DISCHARGE DUCTS 16” on outlet with optional (2) X 12” outlet
THIS HEATER IS FOR USE WITH AND WITHOUT DUCTWORK
WHEN USING DUCTWORK AVOID ANY KINKS OR SHARP BENDS.
INSUFFICIENT INLET AIR OR INSUFFICIENT DISCHARGE AIR WILL CAUSE
THE HEATER TO OVERHEAT.
BLAZE 600 D MAINTENANCE INSTRUCTIONS
WARNING
EVERY CONSTRUCTION HEATER SHOULD BE INSPECTED
BEFORE EACH USE, AND AT LEAST ANNUALLY BY A QUALIFIED SERVICE
PERSON. INCORRECT MAINTENANCE MAY RESULT IN IMPROPER
OPERATION OF THE HEATER AND SERIOUS INJURY COULD OCCUR.
HOSE ASSEMBLIES
The hose assemblies shall be visually inspected prior to each use of the heater. If it is evident there is excessive
abrasion or wear, or the hose is cut, it must be replaced prior to the heater being put into operation. The replacement
hose assembly shall be that specified by the manufacturer.
TEMPERATURE CONTROLLER AND THERMOCOUPLE