Install model cps-un4 – Controlled Products Systems Group CPS-UN4 Manuel d'utilisation
Page 4

4
GROUND OR WALL INSTALLATION
2. Fasten the bracket with the track bolts. NOTE: Always use a fl at
washer next to the radius slot. Putting track bolts in slots will
prevent brackets from pivoting.
3. Attach the bracket assembly to the wall with lag screws
(provided) or to the ground with concrete anchors (not
provided).
4. Insert the sensor into the brackets and fasten with the hex
mounting nut and lock washer.
DOOR TRACK INSTALLATION (FOR GARAGE DOOR ONLY)
2. Drill 1/4" holes in each track and securely fasten the bracket
with the track bolts. NOTE: Always use a fl at washer next to the
radius slot. To vertically attach to 2 x 4 wall stud it may become
necessary to rotate bracket to prevent wood from splitting.
3. Insert the sensor into the bracket and fasten with the hex
mounting nut and lock washer.
The brackets can be mounted on the ground, door track, or wall.
Refer to examples shown below.
1. Determine the confi guration for your brackets. The assembly of
the brackets will vary depending on your installation.
INSTALL MODEL CPS-UN4
ASSEMBLE AND MOUNT THE BRACKETS
Make sure the brackets are aligned so the photoelectric sensors
will face each other across the entrapment zone.
FOR DOORS
Mount sensors no more than 6" (15 cm) above the fl oor and at a
width between 7'-45'.
FOR GATE
Mount within 5" (12.7 cm) of the moving
gate panel with a maximum height of 27.5"
(69.8 cm) above grade (21" (53.3 cm) is
recommended) and at a width between
7'-45'.
The recommended mounting location is on
the inside of the gate.
Assemble to either side
1/2" Hole Spacing
2" Hole Spacing
Flip one bracket and
assemble to either side
Assemble to either side
Flip one bracket and
assemble to either side
1/2" Hole Spacing
2" Hole Spacing
BRACKET ASSEMBLY CONFIGURATIONS
1/4" Flat Washer
1/4" Lock Washer
1/4"-20 Hex Nut
1/4" x 1-1/2"
Lag Screws
1/4"-20 x 5/8"
Track Bolts
1/4"-20 x 5/8"
Track Bolts
Lock Washer for Sensor
Hex Mounting Nut
for Sensor
1/4"-20x5/8"
Track Bolts
1/4" Flat Washer
1/4" Lock Washer
1/4" Hex Nut
1/4" Lock Washer
1/4"-20 Hex Nut
1/4"-20x5/8" Track Bolts
Lock Washer
Hex Mounting Nut
TYPICAL INSTALLATION
1/4" Flat Washer
1/4" Lock Washer
1/4"-20 Hex Nut
/4" Drill
oles
Door
1/4" Lock Was
1/4"-20 Hex N
Lock Washer for Sensor
Hex Mounting Nut
for Sensor
Hex Mounting Nut
Lock Washer
1/4" Flat Washer
1/4" Lock Washer
1/4" Hex Nut
1/4" Lock Washer
1/4"-20 Hex Nut
1/4"-20x5/8" Track Bolts
1/4" Drill
Holes
Door Track
TYPICAL INSTALLATION
GARAGE DOOR
Photoelectric
Sensor
Photoelectric
Sensor
GATE
5" (12.7 cm) max. gap
Edge of Gate Panel
Invisible Light Beam
Photoelectric
Sensor
Photoelectric
Sensor
Mounting
Post
Wall or Fence
27.5" (69.8 cm)
max.
6"
(15 cm)
6"