Warning – Faber AXIA ISOLA Manuel d'utilisation

Page 4

Advertising
background image

Version 02/02 - Page 4

TOOLS NEEDED FOR INSTALLATION

• Saber Saw or Jig Saw

• Drill

• 1 1/4" Wood Drill Bit

• Pliers

• Phillips Screwdriver

• Flat Blade Screwdriver

• Wire Stripper or Utility Knife

• Metal Snips

• Measuring Tape or Ruler

• Level

• Pencil

• Caulking Gun

• Duct Tape

• Crescent Wrench or Socket Set

• Allen Wrench Set

PARTS SUPPLIED FOR INSTALLATION

• 1 Hardware Package

• 1 Literature Package

PARTS NEEDED FOR INSTALLATION

• 2 Conduit Connectors

• Power Supply Cable

• 1 Wall or Roof Cap

• All Metal Ductwork

WARNING

TS - UPPER SUPPORT

TI - LOWER SUPPORT

S - UPPER CHIMNEY COVER

I - LOWER CHIMNEY COVER

C - CANOPY

FIGURE 1

DUE TO THE SIZE AND WEIGHT OF THIS RANGEHOOD,

THE SUPPORT MUST BE FIRMLY ATTACHED TO THE

CEILING. For plaster or sheet rock ceilings, the support must

be attached to the joists. If this is not possible, a support

structure must be built behind the plaster or sheet rock. The

manufacturer assumes no responsibility for injury or damage

caused by improper installations.

FIGURE 2

CALCULATE THE DUCTRUN LENGTH

The ductrun should not exceed 35 feet if ducted with 6" round

ductwork. Calculate the length of the ductwork by adding

the equivalent feet in FIGURE 3 for each piece of duct in the

system An example is given in FIGURE 4. For best results,

use no more than three 90° elbows. Make sure that there is

a minimum of 24" of straight duct between elbows if more than

one is used. Do not install two elbows together.

9 Feet Straight Duct

2 - 90˚ Elbows

Wall Cap
Total System

PLAN THE INSTALLATION

The standard installation for this rangehood is ducted to the outside

of the house. This rangehood can also be installed as ductless

which requires a ductless kit from the dealer which consists of: an

upper chimney cover with a vent hole, vent grate, ductless diverter

and two charcoal filters. The Axia Isola chimney is adjustable and

designed to meet varying ceiling heights. This is accomplished

by using more or less of the upper chimney cover. FIGURE 2

illustrates the dimensions of each piece of the Axia Isola.

9.0 feet

10.0 feet

0.0 feet

19.0 feet

FIGURE 4

7.0 feet

5.0 feet

12.0 feet

0.0 feet

45˚ Elbow

90˚ Elbow

90˚ Flat Elbow

Wall Cap

FIGURE 3

UNPACK THE RANGEHOOD

Remove the rangehood from the carton and place on a flat

surface for assembly. Before discarding the packaging, check

to make sure that no mounting hardware or parts are missing

DO NOT REMOVE THE PLASTIC COVERING ON THE

CHIMNEYS AT THIS TIME! This plastic covering protects the

chimney from scratches during installation.

ATTACHING THE SUPPORT

The rangehood attaches to the ceiling by a metal support (Items

TS and TI in FIGURE 1). This support must be attached to the

ceiling before the canopy is attached. This structure must be

firmly attached to the ceiling.

FOR CONCRETE CEILINGS - Use inserts and screws provided.

FOR WOOD CEILINGS - Use four 4" long wood screws.

FOR PLASTER OR SHEET ROCK CEILINGS - If possible,

the support must be attached to the ceiling joists. If not, a

supporting structure behind the sheet rock must be built.

IMPORTANT NOTE:

F O R D U C T L E S S

INSTALLATIONS

, THE

MINIMUM HEIGHT OF

THE UPPER CHIMNEY IS

GREATER DUE TO THE

SPACE NEEDED FOR

A VENT GRATE THAT

MUST BE EXPOSED

WHERE THE AIR BLOWS

OUT.

!

Advertising