Trouble- shooting, Warning – Homelite HHC35A Manuel d'utilisation

Page 11

Advertising
background image

11

100577

OBSERVED FAULT

POSSIBLE CAUSE

REMEDY

Incorrect pump pressure

Dirty air output, air intake

and lint filters

Dirty fuel filter

Dirt in nozzle

Dirty photocell lens

Defective flame-out control

Heater ignites, but
flame-out control
shuts off heater after
a short period of
time.

WARNING: Disconnect heater cord!

!

Motor hums when
heater is plugged in,
fan rotates slowly or
does not turn.

Solid state relay not

allowed to reset

Binding pump rotor

Heater will not
ignite, but motor runs
for a short period of
time.

Incorrect pump pressure

Carbon deposits on spark

plug and/or improper gap

Dirty fuel filter

Dirt in nozzle

Water in fuel tank

Electronic ignitor not

grounded ectronic ignitor

See Pump Pressure

Adjustment, page 13.

See Air Output, Air Intake

and Lint Filters, page 12.

See Fuel Filter, page 13.

See Nozzle, page 15.

Clean photocell lens.

Replace flame-out control.

Wait two (2) minutes

before trying to restart
heater.

If fan is hard to turn, see

Pump Rotor, page 16.

Motor does not start;
thermostat (if used)
is set to call for heat.

Wait for motor to cool

down. It will reset
automatically.

Motor thermal trip out

TROUBLE-

SHOOTING

To avoid risk of burn and electrical shock, never attempt to
service heater while it is plugged in, operating, or hot.

!

WARNING

See Pump Pressure

Adjustment, page 13.

See Spark Plug, page 14.

See Fuel Filter, page 13.

See Nozzle, page 15.

Drain and flush fuel tank

with clean kerosene. See
Storing, Transporting,
or Shipping,
page 10.

Make sure electronic

ignitor mounting is tight.

Replace electronic ignitor.

WARNING: High voltage!

!

Advertising
Ce manuel est liée aux produits suivants: