6 - conversion for lp or ng gas – Fulgor Milano 600 Series 30 Inch Gas Rangetop Installation Manual Manuel d'utilisation

Page 18

Advertising
background image

EN

14

6 - Conversion for LP or NG Gas

Converting Appliance for Use with LP Gas

WARNING

Conversion is to be performed by an AUTHORIZED
SERVICER (or other qualified agency) in accordance with the
manufacturer’s instructions and all codes and requirements of
the authority having jurisdiction. Failure to follow instructions
could result in serious injury or property damage.
The qualified agency performing this work assumes
responsibility for this conversion.

CAUTION

Before proceeding with the conversion, shut off the gas
supply to the appliance prior to disconnecting the electrical
power

If this appliance is to converted for use with gas LP (propane
or butane), each of the following modifications must be
performed:

Gas conversion label (aluminium) to be placed on the back of
the appliance, near the data plate, after conversion has been
carried out;

Replace Injectors (two ring flame burner)

1. Remove the grates and burner caps.

2. Remove aluminium gas spreader.

3. Remove the three screws from the simmer gas spreader (1).

4. Remove the two screws of the injector cover (2).

5. Remove injector (A) by using a 9-32” (7 mm) nut driver

counter clockwise.

6. Remove injector (B) by using a 9-32” (7 mm) box wrench

counter clockwise.

7. Install the injectors supplied with this appliance in the

appropriate burner. The injectors have small numbers
stamped on the side, this number corresponds with the
orifice diameter and its correct burner location (refer to
illustrations in the section: “Injectors Position”).

8. Turn clockwise to tighten (tighten to a torque of 15 to 20

inch-lbs).

9. Replace all parts following the reverse order.

10. Save the injectors removed from the appliances for future

use.

EXPLODED VIEW OF BURNER

1

2

B

A

Advertising
Ce manuel est liée aux produits suivants: