Schéma de câblage de la powermax1650, Page 9, Pcb3 – Hypertherm Powermax190c Troubleshooting Guide Manuel d'utilisation

Page 66: Control bd, Ci de commande pcb3 del de diagnostic, Câble ruban 40 positions, Rechange

Advertising
background image

U20

U22

(VISIBLE FOR 10 SEC. AFTER EVENT)

TORCH STUCK OPEN

40 POSITION RIBBON CABLE

(VISIBLE FOR 10 SEC. AFTER EVENT)

70

50

STATUS

GAS

45

60

55

65

75

80

85

TSO

SP

SPARE

0.10uF

009994

33

J4

108171

39

40

37

38

35

36

34

008924

0.01uF

100VDC

009990

TP1

IFB

ITF

VACR

C42

50V

R47

100

009073

C32

32

30

31

28

29

26

27

22

25

24

23

21

19

20

009994

HST1

+5

C2

0.10uF

50V

+5

/IOC

009115

10

R5

R4

10

009115

TEMP

PCB4

SENSOR BD

HEATSINK

SENSOR

SA

PRESSURE

1

3

2

B

Y

J5

R

TEMP

SENSOR IN

XFMR

T2

J21

2

B

R

1

3

B

2

SA

FAN

Y

1

J2

1

R

2

B

J1

GAS SOLENOID

SA

B

3

2

R

1

J20

X

+24

10

R107

10

009115

009115

R106

+5

+5

DIAGNOSTIC LED'S

START SIGNAL VALID

INVERTER INTERLOCK

(BLINKING @ 1 SEC. RATE)

SELF DIAGNOSTICS FAILURE

PCB3

CPA

NORMAL

GOUGE

CURRENT

DOWN

MID

UP

CONTROL BD

P1

XFR

SDF

IF

TRANSFER

START

(PE)

BRN

GRN/YEL

BLK

BLU

CE UNIT

CORD

S1

J2

AUX

FILTER

PCB1

J5

(PE)

RED

GRN

AUX

DOMESTIC UNIT

BLK

WHT

S1

CORD

3

10

7

11

18

17

15

16

13

14

12

10

8

9

6

7

4

5

D8

C20

50V

0.10uF

009994

5.1V

1N5231B

109109

OUTB

R16

R6

009883

1/2W

2.21K

009414

499

009036

OUTA

8

+V

7B

-V

7C

9

R12

2.0K

3

1

109223

55V

IRLZ44N

0.022ohm

C10

0.10uF

50V

009994

2

/MM

+24

Q1

2

3

1

J3

B

Y

1

+24

PE

2

MTG-9

1

3

2

4

5

6

3B 3C

4B 4C

6B 6C

5C

5B

13

12

11

1C

1B

2B 2C

16

14

15

042188

ULN2003A

U2

/PREFLOW

/SSR

/PA

t

60V 0.20A

RT9

109024

BRIDGE

~

-

~

~

D24

INPUT

+

GND

CONTROL

-6

COMT

18REG

18T

-6INV

18INV

FLYBACK

SUPPLY

POWER

SYSTEM

T1

18PA

COMPA

+5

+10

+24

PE

CKT

PFC

CONTROL

POWER BD PCB2

SOFT START

K1, K2

VacR

I

Vbus

1

3

2

J8

PFC

IGBT
Q14

C92

+

2

1

J6

3

2

Vbus

J9

PFC CHOKE

C100

+

J7

1

POWER

TRANSFORMER

30 OHM

YEL

J13

YEL

P2

100W

BRN

BRN

INVERTER

IGBT

Q13

T2

ITF

SENSOR

J19

/MM

+24

4

3

COMT

18T

2

1

12

10

11

INTERFACE

GND

CHASSIS

BLK

GRN/YEL

YEL

12

13

14

MACHINE

START

WHT

RED

3

4

CAP

1

COMT

8

9

6

7

4

5

2

3

J18

J17

CKT

J14

WHT

RED

NOZZLE

ELECTRODE

WORK LEAD

TRANSFER

IFB

CURRENT

SENSOR

FEEDBACK

J12

IGBT

PILOT ARC

NC

INDUCTOR

OUTPUT

B

R

OUTPUT

DIODES

J11

15 ohm

100W

129775

WIRE GROUP

129772

123603

005259

NA

041783

POWER SWITCH (S1)

MACHINE INTERFACE CABLE

POWER BD (PCB2)

FILTER (PCB1)

CONTROL BD (PCB3)

123603

041779

005259

041783

041790

041790

100 AMP UNIT

1.41 X Vac

200-600vac

750

INPUT VOLTAGE

Vbus (Vac>541vac)

Vbus (Vac<540vac)

750

NA

059266(DOMESTIC)

059267(CE)

3PH

230-400vac

3PH

TEMP SENSOR BD (PCB4)

041789

041789

TIMING DIAGRAM

013353

013353

LOCKOUT

VIO

ORG

BLUE

NOTES:
1. PIN 7 IS KEYING FEATURE
2. PIN 9 IS LOCKOUT FEATURE

6

5

+

-

+24

24VDC @100MA MAX

J1

J3

J4

J6

129773

7.5 ohm
100W

009115

R9

10

C12

0.10uF

R

15 ohm

100W

KEY

J10

HST

013352

ELEC SCHEM:100A SYS

1 OF 1

A

Schéma de câblage de la Powermax1650

page 9

CI DE COMMANDE

PCB3

DEL DE DIAGNOSTIC

SIGNAL D’AMORÇAGE VALIDE

TRANSFERT

DÉFAILLANCE DE L’AUTODIAGNOSTIC
(CLIGNOTEMENT TOUTES LES SECONDES)

TORCHE BLOQUÉE EN POSITION OUVERTE
(VISIBLE PENDANT LES 15 SECONDES QUI

SUIVENT L’ÉVÉNEMENT)

RECHANGE

CÂBLE RUBAN 40 POSITIONS

APPAREIL 100 A

059266(Domestique)

059267(CE)

TENSION D’ENTRÉE

200–600V c.a.

230–400V c.a.

triphasé

triphasé

Vbus (V c.a. < 540 V c.a.)

750

750

Vbus (V c.a. < 541V c.a.)

1.41 X V c.a.

GROUPE DE FILS

129772

129775

CÂBLE D’INTERFACE MACHINE

123603

123603

INTERRUPTEUR D’ALIMENTATION (S1)

005259

005259

FILTRE (PCB1)

041779

CI D’ALIMENTATION (PCB2)

041783

041783

CI DE COMMANDE (PCB3)

041790

041790

CAPTEUR DE TEMPÉRATURE (PCB4)

041789

041789

CI CAPTEUR DE TEMPÉRATURE

013353

013353

INTERVERROUILLAGE DE SÛRETÉ DE L’ONDULEUR
(VISIBLE PENDANT LES 15 SECONDES QUI

SUIVENT L’ÉVÉNEMENT)

Advertising