TROUBLESHOOTING

9

PROBLEM

POSSIBLE CAUSE

SOLUTIONS

1) Unit does not work

• Power is out.

• The plug is not plugged in properly.

• The full-tank indicator is ON; tank is

full.

• Current leaking or pressing test

button on LCDI plug.

• Wait for power to return.

• Plug in properly.

• Remove drain water from the drain

tank.

• Press the reset button after resolving

problem.

2) Unit suddenly stops during operation.

• Indoor set temperature has been

reached.

• The preset time is up.

• The full-tank indicator is ON; tank is

full.

• Reset the temperature level.

• Reset the timer.

• Remove drain water from the drain

tank.

3) Unit runs intermittently

• Malfunction.

• Surrounding temp. is too high/low.

• Exhaust duct hose is blocked.

• Contact your dealer.

• This is normal.

• Check the duct hose.

4) Unit functions but the room is not

cooled.

• Window or door is open in room.

• There is a heat source or too many

people in the room.

• Air intake grill is clogged.

• Filter is too dirty.

• Temperature setting is too high.

• Close all windows/doors.

• Move any heat sources from room.

• Clean air intake grill.

• Replace the filter.

• Lower temp. setting.

5) Condensed water spills out when

moving the unit.

• The tank is nearly full.

• Remove drain plug on rear bottom

and drain out water.