Venting installation, Optional outside air kit (model ak4/ak4f), Chimney pipe – Desa (V)C36LH Manuel d'utilisation

Page 7

Advertising
background image

www.desatech.com

107777-01E

7

Figure 8 - Lineal Gain

Figure 7 - Outside Air Kit

Secure to Collars with Metal Tape, Screws
or Straps (Min. of 1/4" x 20" in size)

Air Inlet
Location
Must Allow
For Bushes
or Snow

Vent Hood
Required for
Wall Installation

Air Inlet
Eyebrow

Vented Crawl Space
(Check Local Codes
Before Installing in a
Vented Crawl Space)

OPTIONAL OUTSIDE AIR KIT
(MODEL AK4/AK4F)

Installation of an outside air kit should be
performed during rough framing of fireplace
due to the nature of it's location. Outside com-
bustion air is accessed through a vented crawl
space (AK4F) or through a sidewall (AK4).
See Figure 24 on page 15 for instruction of
operating air kit.

CAUTION: Combustion air

inlet ducts shall not terminate

in attic space.

The maximum height for the

air vent can not exceed 3 feet

below the flue gas outlet of the

termination.

VenTIng InsTallaTIon

CHIMNEY PIPE

DESA Heating, LLC chimney system consists
of 12", 18", 24", 36" and 48" snap-lock, dou-
ble-wall pipe segments, planned for maximum
adaptability to individual site requirements.
Actual lengths gained after fitting overlaps
must be taken into consideration (lineal
gain) and are given in lineal gain chart (see
Figure 8). Lineal gain is actual measurable
length of a part after two or more parts are
connected. For Canada, use chimney parts
designated "HT".

WARNING: The opening in

collar around chimney at top of

fireplace must not be obstructed.

Never use blown insulation to fill

chimney enclosure.

Hemmed
End

8" Stainless
Inner Pipe

12

3

/

8

"

Galvanized
Outer Pipe

LINEAL GAIN

PART NO.

DESCRIPTION

GAIN

36"

Fireplace

37

1

/

2

"

12-8DM

12-8HT

Pipe Section

10

5

/

8

"

18-8DM

18-8HT

Pipe Section

16

5

/

8

"

24-8DM

24-8HT

Pipe Section

23

5

/

8

"

36-8DM

36-8HT

Pipe Section

34

5

/

8

"

48-8DM

48-8HT

Pipe Section

46

5

/

8

"

RT-8DM

Round Termination

6

7

/

8

"*

RTL-8DM

Round Termination

7

3

/

4

"*

RTT-8DM

Round Termination

with Slip Section

6

7

/

8

" to

23

1

/

8

"*

RTTL-8DM

Round Termination

with Slip Section

8

1

/

2

" to

21

1

/

2

"*

ET-8DM

Square Chase-Top

12"*

ETO-8DM

Square Chase-Top

with Mesh

12"*

ETL-8DM

Square Chase-Top

with Slip Section

7" to 15"*

ETLO-8DM

Square Chase-Top

with Mesh & Slip

Section

12" to

25

1

/

2

"*

* The lineal gain for the terminations is
measured to the flue gas outlet height.