Fireplace installation, Fan/blower kit assembly, Continued – Desa (V)C36LH Manuel d'utilisation

Page 6: Mantels

Advertising
background image

www.desatech.com

107777-01E

6

FAN/BLOWER KIT ASSEMBLY

Fan or blower kit is optional with this fireplace
(circulating models only). Use of blowers or
fans other than those manufactured by DESA
Heating, LLC voids warranty. Fan is operated
by pressing rocker switch (see Figure 6) in
lower right hand corner of fireplace face.
Blower is operated by turning control knob
(not shown).
Fan/blower kit electrical connections are
made through the electrical cover plate on
side of fireplace a shown in Figure 6.

FIreplaCe InsTallaTIon

Continued

12

1

/

4

" Ref.

6"

Ref.

12" Min.

9" Min.

1

1

/

2

" Max.

3" Nom.

33°

Combustible
Material

Safe
Zone for
Projection of
Combustible
Materials

Fireplace Opening

Upper

Section of

Fireplace

Figure 4 - Mantel Clearances to

Combustible Material (with Louver)

Wiring Instructions
1. Remove electrical cover plate with bush-

ing from fireplace by removing 2 sheet
metal screws as shown in Figure 6.

2. Slide power source wiring through electri-

cal bushing opening and electrical cover
plate and make all necessary connec-
tions.

3. Slide all wiring connections in electrical

housing as shown in Figure 6.

4. Secure electrical cover plate with screws

previously removed.

Note: Electrical housing and cover plate have
sharp edges. Wear protective gloves.

MANTELS

A mantel may be installed if desired (see
Figures 4 and 5). Woodwork such as wood
trims, mantels or any other combustible
material projecting from front face, must not
be placed within 9" of fireplace opening and
within 6" of top louver opening. Combustible
materials above 9" and projecting more than
1

1

/

2

" from fireplace must not be placed less

than 12" from top opening of fireplace (NFPA
STD 211, Sec. 7-3.3.3).

Figure 5 - Mantel Clearances to

Combustible Material (without Louver)

12

1

/

4

" Ref.

1

1

/

2

"

Max.

Upper Section

of Circulating

Fireplace

6"

Ref.

6"

Min.

33°

3" Nom.

*Note: Drawing

Not To Scale

Safe Zone For

Projection of

Combustible

Materials

Combustible

Material

12"

Min.

9"

Min.

Fireplace Opening

Top of

Louvered

Opening

Electrical
Bushing

Electrical
Cover
Plate

Rocker
Switch

Figure 6 - Fan Switch-Electrical Bushing

Electrical
Housing

Wire Nut (3x)
(Not Supplied)

Outer Wrapper
of Fireplace

Electrical Cover
Plate and
Electrical Bushing

Fireplace Chassis
Ground

To Power
Source

Receptacle
(Supplied)

Power Source Wiring
(Not Supplied)

Prewired Receptacle
and Ground

Sheet
Metal
Screws

Advertising