Occasionally, a problem may occur that is minor, and a service call may not be necessary. Use this
troubleshooting guide for a possible solution. If the unit continues to operate improperly, call an authorized
service depot or Danby’s Toll Free Number for assistance: 1-800-26-

(1-800-263-2629)

TROUBLESHOOTING

NOTES:
1)
If circuit breaker is tripped repeatedly, or fuse is blown more than once, contact a qualified technician.

2) When unit is installed using proper installation steps, unit is properly tipped toward the outdoors to allow for

condensation run-off.

PROBLEM

POSSIBLE CAUSE

SOLUTION

1) Air conditioner will not operate.

• No power to the unit.

• Check connection of power cord to

power source.

• Check fuse or circuit breaker.
• Set SELECTOR SWITCH to

position other than “OFF”.

• The power cord “RESET” button

must always be pushed in (engaged)
for correct operation.

2) Inefficient or no cooling.

• Dirty air filter.
• Unit size inappropriate for application
• Blocked air flow.
• Power interruption, settings changed

too quickly, or compressor overload
tripped.

• Clean/replace air filter.
• Check with dealer to determine

proper unit capacity for application.

• Remove obstruction from grill or

outdoor louvres.

• Turn the unit off and wait 5

minutes before attempting to restart.

3) Noisy unit

• Loose parts.
• Inadequate support.

• Tighten loose parts.
• Provide additional support to unit.

4) Odors

• Formation of mold, mildew, or algae

on wet surfaces.

• Clean unit thoroughly.
• Place algaecide tablet in base pan.

5) Water dripping outside

• Hot and humid weather.

• Condensation run-off is normal under

these conditions.

6) Water dripping inside

• Unit is not properly angled to allow

water to drain outside.

• Unit must be installed on an angle for

proper condensation run-off. Check
the unit and make any adjustments.

7) Ice or frost build-up.

• Low outside temperature
• Unit air filter is dirty

• When outdoor temperature is

approximately 18.3°C (65°F) or
below, frost may form when unit is in
cooling mode. Switch unit to FAN
(only) operation until frost melts.

• Remove and clean filter.