1. Using a sharp object, pry out the 3 plug buttons. Save the plugs for
later use.
2. Remove the upper hirige cover.
3. Remove the 2 philips screws which connect the upper hinge to
the cabinet top.
4. Carefully lift the doqr, placing it on a padded suiface to avoid scratching.
5
.
Set the refrigerator door in its new position, making sure the hinge
pin enters the bushing at the bottom of the cabinet.
6. While holding door in the closed position, loosely secure the upper hinge
using the parts removed in step 3. Before tightening the screws, make
sure the top of the door is leveled with the cabinet top.
7. Replace upper hinge cover.
8. Replace all 3 plugs removed in step 1 to cover the holes at the right.
TROUBLESHOOTING-PROBLEM SOLVER
PROBLEM
PROBABLE CAUSES
SOLUTION
Refrigerator does
not operate
No Power
Defective Plug
Thermostat is in the •
**OFF”position
120V AC cord is not
plugged - in
• Circuit Breaker Tripped
• Fuse Blown
■ Replace it or fix it
• Set dial to position
"NORMAL
• Connect power cord
to three prong wall
outlet
Not cold enough
Thermostat Dial Set
in incorrect position
Frequent door openings
let cold air escape
• Read instruction
manual (Paragraph
refeiring to temperature
control)
* Avoid opening door
too many times
Abnormal noises,
vibration
Not Leveled
Refrigerant gas
expanding in evaporator
Tubes or Coils too
close to wall
• Adjust leveling screw
• Normal operation
• Check for proper
clearance from walls, etc
Cabinet odor
Food
• Check for spoiled food
• Use tight covers
• Clean interior