1. Using a sharp object, pry out the 3 plug buttons. Save the plugs for

later use.

2. Remove the upper hirige cover.
3. Remove the 2 philips screws which connect the upper hinge to

the cabinet top.

4. Carefully lift the doqr, placing it on a padded suiface to avoid scratching.
5

.

Set the refrigerator door in its new position, making sure the hinge

pin enters the bushing at the bottom of the cabinet.

6. While holding door in the closed position, loosely secure the upper hinge

using the parts removed in step 3. Before tightening the screws, make
sure the top of the door is leveled with the cabinet top.

7. Replace upper hinge cover.

8. Replace all 3 plugs removed in step 1 to cover the holes at the right.

TROUBLESHOOTING-PROBLEM SOLVER

PROBLEM

PROBABLE CAUSES

SOLUTION

Refrigerator does

not operate

No Power

Defective Plug

Thermostat is in the •

**OFF”position

120V AC cord is not

plugged - in

• Circuit Breaker Tripped
• Fuse Blown

■ Replace it or fix it

• Set dial to position

"NORMAL

• Connect power cord

to three prong wall

outlet

Not cold enough

Thermostat Dial Set

in incorrect position

Frequent door openings

let cold air escape

• Read instruction

manual (Paragraph
refeiring to temperature
control)

* Avoid opening door

too many times

Abnormal noises,

vibration

Not Leveled
Refrigerant gas
expanding in evaporator

Tubes or Coils too

close to wall

• Adjust leveling screw
• Normal operation
• Check for proper

clearance from walls, etc

Cabinet odor

Food

• Check for spoiled food
• Use tight covers
• Clean interior